EUVIMEDEUVIMED entdecken
Crossref

Detecting EPO in Microvolumetric Capillary Serum Shipped at Ambient Temperature for Antidoping Testing

Geoffrey D Miller iD, Jenna M Goodrum iD, America K Flores, Andre K Crouch, Daniel Eichner

Drug Testing and Analysis · 2025

DOI: 10.1002/dta.3831 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Drug Testing and Analysis, 2025. Verfasst von Geoffrey D Miller und 4 weiteren Autor:innen. Beteiligte Einrichtung: Sports Medicine Research and Testing Laboratory, Salt Lake City, Utah, USA. Hauptthemen laut MEDLINE: Doping in Sports, Erythropoietin, Substance Abuse Detection, Specimen Handling. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 5 Literaturangaben. Gefördert von: Ultimate Fighting Championship, Sports Medicine Research and Testing Laboratory.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Erythropoietin receptor agonist (ERA) testing for antidoping can be achieved in both urine and blood samples. Recent published work showed the comparability between the two matrices and focused on detectability in microvolumetric capillary serum samples collected using the Tasso+ device. Currently, in the antidoping field, blood samples are required to be shipped under cold, temperature‐controlled conditions. However, due to the suggested greater stability of EPO in blood compared to urine, it is believed that blood samples should be viable for ERA analysis if shipped under the ambient, not cold temperature‐controlled conditions to which urine samples are subjected. In this collaborative study with the Ultimate Fighting Championship, microvolumetric capillary serum samples were collected in the field and shipped under ambient conditions to the laboratory for ERA analysis. Resulting data showed that endogenous EPO was detectable in 100% of these samples, showing no loss in detectability despite shipping under non‐controlled conditions. Further, ERA analyses were conducted in the laboratory on additional in‐house collected samples and post‐EPO administration samples subjected to various storage and shipping conditions, also showing reliable endogenous and recombinant EPO detectability in all samples except those experiencing extreme temperature (50°C) conditions. Taken together, these data highlight the stability of EPO in blood samples and show that ERA blood samples can be collected in the field and shipped without costly temperature‐controlled shipping methods and without a loss in detectability.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Doping in SportsErythropoietinSubstance Abuse DetectionSpecimen HandlingHumansTemperature

Stichwörter der Autor:innen

EPOTasso+antidopingcapillary serum

Substanzen

ErythropoietinEPO protein, human

Autor:innen und Institutionen

  • Sports Medicine Research and Testing Laboratory, Salt Lake City, Utah, USA.

ORCID-Profile: Geoffrey D Miller, Jenna M Goodrum

Förderung

  • Ultimate Fighting Championship
  • Sports Medicine Research and Testing Laboratory

Zitieren

APA

Miller, G. D., Goodrum, J. M., Flores, A. K., Crouch, A. K., & Eichner, D. (2025). Detecting EPO in Microvolumetric Capillary Serum Shipped at Ambient Temperature for Antidoping Testing. Drug Testing and Analysis. https://doi.org/10.1002/dta.3831

Vancouver

Miller GD, Goodrum JM, Flores AK, Crouch AK, Eichner D. Detecting EPO in Microvolumetric Capillary Serum Shipped at Ambient Temperature for Antidoping Testing. Drug Testing and Analysis. 2025. doi:10.1002/dta.3831

BibTeX
@article{Miller2025,
  author = {Miller, Geoffrey D and Goodrum, Jenna M and Flores, America K and Crouch, Andre K and Eichner, Daniel},
  title = {Detecting EPO in Microvolumetric Capillary Serum Shipped at Ambient Temperature for Antidoping Testing},
  journal = {Drug Testing and Analysis},
  year = {2025},
  doi = {10.1002/dta.3831}
}
Kostenlos starten →