EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Stability of carboxy‐hemoglobin during storage at different temperatures

Nadine B Wachsmuth iD, Bassem Bajaa, Christian Wachsmuth, Walter F J Schmidt iD

Drug Testing and Analysis · 2025

DOI: 10.1002/dta.3710 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Drug Testing and Analysis, 2025. Verfasst von Nadine B Wachsmuth und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Sports Medicine/Sports Physiology, University of Bayreuth, Bayreuth, Germany. Hauptthemen laut MEDLINE: Carboxyhemoglobin. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate determination of carboxy‐hemoglobin (COHb%) is essential for the assessment of hemoglobin mass (Hbmass) by CO‐rebreathing. To analyze blood samples for a certain period of time after blood collection, it is necessary to know the stability of the COHb% during storage. The aim of the study was to determine the stability of COHb% at different storage temperatures over a period of up to 3 months. Twenty‐five milliliters of cubital venous blood was taken from five volunteers (three females and two males) before and after inhalation of 0.8/1.0 mL/kg carbon monoxide and stored at +20°C and +4°C for 6 days and at −70°C for 12 weeks. Within the first 6 days, the blood was analyzed daily, then weekly for 12 weeks. Additionally, Hbmass was determined in 13 endurance athletes immediately after blood collection and after storage for 3 days (eight cyclists) and 7 days (five swimmers) at +20°C or +4°C. COHb% before and after CO inhalation was 1.56 ± 0.48 and 5.86 ± 1.12%, respectively, and remained unchanged over 6 days, with no difference between storage at different temperatures. The standard deviation (STD) over time was between 0.07% and 0.12%. Similarly, storage at −70°C for 12 weeks did not change COHb%, whereas STD was 0.07%. Hbmass determined immediately and, after 3 or 7 days of storage, differed by 10 ± 7 g and 15 ± 11 g corresponding to a typical error of 0.8% and 1.1%. Blood storage at +20°C and +4°C for 6 days and at −70°C for 12 weeks does not affect COHb% and has, therefore, no influence on Hbmass assessment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CarboxyhemoglobinHumansMaleFemaleTemperatureAdultYoung AdultTime FactorsCarbon Monoxide

Stichwörter der Autor:innen

CO‐rebreathingaccuracycarbon monoxidehemoglobin massreliability

Substanzen

CarboxyhemoglobinCarbon Monoxide

Autor:innen und Institutionen

  • Division of Sports Medicine/Sports Physiology, University of Bayreuth, Bayreuth, Germany.
  • Division of Exercise Physiology and Metabolism, Bayreuth Centre of Sport Science, University of Bayreuth, Bayreuth, Germany.

ORCID-Profile: Nadine B Wachsmuth, Walter F J Schmidt

Zitieren

APA

Wachsmuth, N. B., Bajaa, B., Wachsmuth, C., & Schmidt, W. F. J. (2025). Stability of carboxy‐hemoglobin during storage at different temperatures. Drug Testing and Analysis. https://doi.org/10.1002/dta.3710

Vancouver

Wachsmuth NB, Bajaa B, Wachsmuth C, Schmidt WFJ. Stability of carboxy‐hemoglobin during storage at different temperatures. Drug Testing and Analysis. 2025. doi:10.1002/dta.3710

BibTeX
@article{Wachsmuth2025,
  author = {Wachsmuth, Nadine B and Bajaa, Bassem and Wachsmuth, Christian and Schmidt, Walter F J},
  title = {Stability of carboxy‐hemoglobin during storage at different temperatures},
  journal = {Drug Testing and Analysis},
  year = {2025},
  doi = {10.1002/dta.3710}
}
Kostenlos starten →