Prevalence of nandrolone preparations with endogenous carbon isotope ratios in Australia
Drug Testing and Analysis · 2024
DOI: 10.1002/dta.3654 ↗Kurz gefasst
Fachartikel in der Zeitschrift Drug Testing and Analysis, 2024. Verfasst von Michael Polet und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic Sciences, Doping Control Laboratory, Ghent University, Ghent, Belgium. Hauptthemen laut MEDLINE: Nandrolone, Carbon Isotopes, Anabolic Agents, Doping in Sports. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 10 Literaturangaben. Gefördert von: Sport Integrity Australia.
Abstract (Originalsprache)
Nandrolone and its prohormones, including 19‐norandrost‐4‐ene‐3,17‐dione and 19‐norandrost‐4‐ene‐3β,17β‐diol, are anabolic steroids forbidden at all times in sports according to the World Anti ‐ Doping Code Prohibited List and its metabolite 19‐norandrosterone (19NA) is the preferred urinary target compound to identify their abuse. In recent years, an increasing number of 19NA isotope ratio mass spectrometry (IRMS) cases have arisen that, based on the initial testing procedure, were likely to result in an adverse analytical finding but were concluded negative after IRMS analysis. The current study was therefore set up to gain a better insight on the prevalence of nandrolone preparations with endogenous carbon isotope ratio values in Australia. Suitable workplace (non‐athlete) urine samples that had previously been reported positive for 19NA were identified and analysed on IRMS. A total of 82% of the samples that were analysed were reported with enriched carbon isotope ratios of 19NA (i.e., 19NA greater than −26‰). This indicates that there is a high prevalence of nandrolone‐containing anabolic androgenic steroid preparations in Australia that have ‘endogenous’ carbon isotope ratios which reduces the ability to identify exogenous nandrolone.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Diagnostic Sciences, Doping Control Laboratory, Ghent University, Ghent, Belgium.
- Australian Sports Drug Testing Laboratory, National Measurement Institute, Sydney, New South Wales, Australia.
- Sport Integrity Australia, Fyshwick, Australian Capital Territory, Australia.
ORCID-Profile: Michael Polet
Förderung
- Sport Integrity Australia
Zitieren
APA
Polet, M., Van Eenoo, P., Brooker, L., Edey, C., Agon, V., Grainger, J., Payne, G., & Goebel, C. (2024). Prevalence of nandrolone preparations with endogenous carbon isotope ratios in Australia. Drug Testing and Analysis. https://doi.org/10.1002/dta.3654
Vancouver
Polet M, Van Eenoo P, Brooker L, Edey C, Agon V, Grainger J, et al. Prevalence of nandrolone preparations with endogenous carbon isotope ratios in Australia. Drug Testing and Analysis. 2024. doi:10.1002/dta.3654
BibTeX
@article{Polet2024,
author = {Polet, Michael and Van Eenoo, Peter and Brooker, Lance and Edey, Claire and Agon, Vanessa and Grainger, Janelle and Payne, Gemma and Goebel, Catrin},
title = {Prevalence of nandrolone preparations with endogenous carbon isotope ratios in Australia},
journal = {Drug Testing and Analysis},
year = {2024},
doi = {10.1002/dta.3654}
}
EUVIMED