EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Efficacy of Endoscopic Ultrasound‐guided Fine Needle Biopsy With Simplified Macroscopic On‐site Evaluation (With Video)

Kento Shionoya, Ryosuke Tonozuka, Shuntaro Mukai iD, Yuki Joyama, Takayoshi Tsuchiya, Reina Tanaka, Kenjiro Yamamoto, Kazumasa Nagai, Yukitoshi Matsunami, Hiroyuki Kojima iD, Hirohito Minami, Noriyuki Hirakawa iD und 2 weitere

DEN Open · 2027-04 · 7 (1)

DOI: 10.1002/deo2.70347 ↗

Kurz gefasst

Fachartikel in der Zeitschrift DEN Open, online erschienen am 27.06.2026. Verfasst von Kento Shionoya und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology and Hepatology Tokyo Medical University Tokyo Japan. Die Arbeit nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and Aims With advances in preoperative chemotherapy and comprehensive genomic profiling, endoscopic ultrasound‐guided fine needle biopsy (EUS‐FNB) has become vital for diagnosing pancreatic and peridigestive tract lesions. However, evidence remains limited regarding the performance of new‐generation puncture needles and simplified specimen evaluation methods. This study retrospectively assessed the diagnostic ability and procedural adverse events (AEs) of a new‐generation puncture needle for solid pancreatic, subepithelial, and other lesions.

Methods

We analyzed data from 1232 consecutive patients who underwent EUS‐FNB between August 2016 and November 2023 at a single care center. Specimen processing was performed using the simplified macroscopic on‐site evaluation (S‐MOSE) method, which does not require additional pathological tests such as rapid on‐site evaluation or cytology.

Results

The overall diagnostic accuracy using S‐MOSE was 93.7%. Specifically, the diagnostic accuracy for pancreatic cancer was 95.8%. The AE rate was 1.1% (14/1232), including pancreatitis (six), hemorrhage (five), hematoma (two), and pancreatic fistulas (one). The first puncture diagnostic rate was 83.6%, which increased to 92.5% after the second puncture, with only a marginal gain of 1.2% beyond the third puncture. Multivariable analysis identified smaller lesion size and benign pathology as factors associated with lower diagnostic accuracy; conversely, malignant pathology was associated with higher diagnostic accuracy (odds ratio 1.895, p = 0.011).

Conclusion

EUS‐FNB with S‐MOSE, typically requiring up to two punctures, provides efficient and accurate histopathological diagnosis across diverse lesions while minimizing procedural burden. Trial Registration : N/A.

Schlagwörter

Stichwörter der Autor:innen

S‐MOSEendoscopic ultrasound‐guided fine needle biopsyendoscopic ultrasound‐guided tissue acquisitionmacroscopic on‐site evaluationpancreatic cancer

Autor:innen und Institutionen

  • Department of Gastroenterology and Hepatology Tokyo Medical University Tokyo Japan.

ORCID-Profile: Shuntaro Mukai, Hiroyuki Kojima, Noriyuki Hirakawa

Zitieren

APA

Shionoya, K., Tonozuka, R., Mukai, S., Joyama, Y., Tsuchiya, T., Tanaka, R., Yamamoto, K., Nagai, K., Matsunami, Y., Kojima, H., Minami, H., Hirakawa, N., Asano, K., & Itoi, T. (2027). Efficacy of Endoscopic Ultrasound‐guided Fine Needle Biopsy With Simplified Macroscopic On‐site Evaluation (With Video). DEN Open, 7(1). https://doi.org/10.1002/deo2.70347

Vancouver

Shionoya K, Tonozuka R, Mukai S, Joyama Y, Tsuchiya T, Tanaka R, et al. Efficacy of Endoscopic Ultrasound‐guided Fine Needle Biopsy With Simplified Macroscopic On‐site Evaluation (With Video). DEN Open. 2027;7(1). doi:10.1002/deo2.70347

BibTeX
@article{Shionoya2027,
  author = {Shionoya, Kento and Tonozuka, Ryosuke and Mukai, Shuntaro and Joyama, Yuki and Tsuchiya, Takayoshi and Tanaka, Reina and Yamamoto, Kenjiro and Nagai, Kazumasa and Matsunami, Yukitoshi and Kojima, Hiroyuki and Minami, Hirohito and Hirakawa, Noriyuki and Asano, Kyoko and Itoi, Takao},
  title = {Efficacy of Endoscopic Ultrasound‐guided Fine Needle Biopsy With Simplified Macroscopic On‐site Evaluation (With Video)},
  journal = {DEN Open},
  year = {2027},
  volume = {7},
  number = {1},
  doi = {10.1002/deo2.70347}
}
Kostenlos starten →