EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Third‐Generation Narrow‐Band Imaging Versus White‐Light Imaging for the Detection of Early Gastric Cancer: A Randomized Controlled Study

Yukihisa Fujinaga, Hitoshi Mori, Masayoshi Takami, Hiroyuki Masuda, Jun-Ichi Hanatani, Satoshi Iwai, Shohei Asada, Akihiko Shibamoto, Yuki Tsuji, Koh Kitagawa iD, Norihisa Nishimura, Shinya Sato und 4 weitere

DEN Open · 2026-04 · 6 (1)

DOI: 10.1002/deo2.70288 ↗

Kurz gefasst

Fachartikel in der Zeitschrift DEN Open, online erschienen am 04.02.2026. Verfasst von Yukihisa Fujinaga und 15 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology Nara Medical University Kashihara, Nara Japan. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

The endoscopic system EVIS X1 with improved image quality has been introduced into clinical practice. We examined whether third‐generation narrow‐band imaging (3G‐NBI) is more effective than white‐light imaging (WLI) for detecting early gastric cancer (EGC).

Methods

Our study, performed at a single center, had a parallel‐group, open‐label, two‐arm, randomized, controlled design. Patients who had undergone endoscopic submucosal dissection for EGC were randomly assigned to a group undergoing 3G‐NBI after initial WLI (initial WLI group) or a group undergoing WLI after initial 3G‐NBI (initial 3G‐NBI group). The primary endpoint was the EGC detection rate of the two methods. The secondary endpoints were as follows: proportions of EGC detected and missed lesions, positive predictive value (PPV) for EGC diagnosis, and observation time for WLI and 3G‐NBI.

Results

The EGC detection rate was 9.0% (17/188) in the initial WLI group and 8.5% (16/188) in the initial 3G‐NBI group. The missed lesion rate was 5.6% (1/18) in the initial WLI group and 0% (0/18) in the initial 3G‐NBI group. The PPV of the initial WLI group was 42.5% (17/40), whereas that of the secondary 3G‐NBI was 25% (1/4). The PPV of the initial 3G‐NBI group was 30.2% (16/53). No biopsies were performed during secondary WLI. The examination times were 274 ± 78.2 and 280 ± 82.9 s for WLI and 3G‐NBI, respectively.

Conclusions

3G‐NBI was not superior to WLI in detecting EGC. This finding is likely due to improved WLI image quality.

Schlagwörter

Stichwörter der Autor:innen

detection rate of early gastric cancergastric cancergastrointestinal endoscopynarrow‐band imagingwhite‐light imaging

Autor:innen und Institutionen

  • Department of Gastroenterology Nara Medical University Kashihara, Nara Japan.
  • Division of Endoscopy Nara Medical University Nara Japan.

ORCID-Profile: Koh Kitagawa

Zitieren

APA

Fujinaga, Y., Mori, H., Takami, M., Masuda, H., Hanatani, J. I., Iwai, S., Asada, S., Shibamoto, A., Tsuji, Y., Kitagawa, K., Nishimura, N., Sato, S., Kaji, K., Namisaki, T., Mitoro, A., & Yoshiji, H. (2026). Third‐Generation Narrow‐Band Imaging Versus White‐Light Imaging for the Detection of Early Gastric Cancer: A Randomized Controlled Study. DEN Open, 6(1). https://doi.org/10.1002/deo2.70288

Vancouver

Fujinaga Y, Mori H, Takami M, Masuda H, Hanatani JI, Iwai S, et al. Third‐Generation Narrow‐Band Imaging Versus White‐Light Imaging for the Detection of Early Gastric Cancer: A Randomized Controlled Study. DEN Open. 2026;6(1). doi:10.1002/deo2.70288

BibTeX
@article{Fujinaga2026,
  author = {Fujinaga, Yukihisa and Mori, Hitoshi and Takami, Masayoshi and Masuda, Hiroyuki and Hanatani, Jun-Ichi and Iwai, Satoshi and Asada, Shohei and Shibamoto, Akihiko and Tsuji, Yuki and Kitagawa, Koh and Nishimura, Norihisa and Sato, Shinya and Kaji, Kosuke and Namisaki, Tadashi and Mitoro, Akira and Yoshiji, Hitoshi},
  title = {Third‐Generation Narrow‐Band Imaging Versus White‐Light Imaging for the Detection of Early Gastric Cancer: A Randomized Controlled Study},
  journal = {DEN Open},
  year = {2026},
  volume = {6},
  number = {1},
  doi = {10.1002/deo2.70288}
}