Endoscopic Ultrasound‐guided Fine‐Needle Biopsy With End‐Cutting Needles in Autoimmune Pancreatitis: A Systematic Review and Meta‐Analysis
DEN Open · 2026-04 · 6 (1)
DOI: 10.1002/deo2.70239 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift DEN Open, online erschienen am 04.11.2025. Verfasst von Antonio Facciorusso und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Experimental Medicine Università del Salento Lecce Italy. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objectives
There is limited evidence on the diagnostic yield of endoscopic ultrasound (EUS)‐guided tissue acquisition (TA) using fine‐needle biopsy (FNB) in autoimmune pancreatitis (AIP), particularly considering the newer end‐cutting needles. The aim of this meta‐analysis was to provide a pooled estimate of the diagnostic performance of EUS‐TA using FNB in AIP patients according to the needle type used.
Methods
A computerized bibliographic search was performed through April 2024. Pooled effects were calculated using a random‐effects model. The primary endpoint was diagnostic accuracy. Secondary outcomes were sample adequacy, rates of adequate material for levels 1 and 2 of histological diagnosis, definitive diagnosis reached with histology in addition to imaging/laboratory tests, and safety.
Results
Twelve studies (three prospective series and one randomized trial) with 496 patients were included. Overall diagnostic accuracy rate was 75% (66%–83%), with a superiority of end‐cutting needles over reverse bevel needles (80%, 70%–90% versus 49%, 21%–67%; p < 0.001). Franseen (81%, 68%–93%) and Fork‐tip needles (86%, 74%–98%) showed the highest accuracy. Sample adequacy rate was 92% (87%–98%), and EUS‐TA using FNB provided level 1 of histological diagnosis in 47% of cases (38%–57%) and level 2 in 23% (16%–30%). EUS‐TA using FNB provided a definitive diagnosis in 77% (63%–91%) of cases. Pooled rate of adverse event was 2% (1%–3%), mainly mild pancreatitis.
Conclusions
End‐cutting needles showed high diagnostic yield in patients with AIP, with a low rate of adverse events, and should be preferred over reverse bevel needles.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Experimental Medicine Università del Salento Lecce Italy.
- Department of Medicine Gastroenterology and Digestive Endoscopy University of Verona Verona Italy.
ORCID-Profile: Stefano Francesco Crinò
Zitieren
APA
Facciorusso, A., Bellocchi, M. C. C., De Pretis, N., Frulloni, L., & Crinò, S. F. (2026). Endoscopic Ultrasound‐guided Fine‐Needle Biopsy With End‐Cutting Needles in Autoimmune Pancreatitis: A Systematic Review and Meta‐Analysis. DEN Open, 6(1). https://doi.org/10.1002/deo2.70239
Vancouver
Facciorusso A, Bellocchi MCC, De Pretis N, Frulloni L, Crinò SF. Endoscopic Ultrasound‐guided Fine‐Needle Biopsy With End‐Cutting Needles in Autoimmune Pancreatitis: A Systematic Review and Meta‐Analysis. DEN Open. 2026;6(1). doi:10.1002/deo2.70239
BibTeX
@article{Facciorusso2026,
author = {Facciorusso, Antonio and Bellocchi, Maria Cristina Conti and De Pretis, Nicolò and Frulloni, Luca and Crinò, Stefano Francesco},
title = {Endoscopic Ultrasound‐guided Fine‐Needle Biopsy With End‐Cutting Needles in Autoimmune Pancreatitis: A Systematic Review and Meta‐Analysis},
journal = {DEN Open},
year = {2026},
volume = {6},
number = {1},
doi = {10.1002/deo2.70239}
}
EUVIMED