EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Troubleshooting of Endoscopic Ultrasound‐guided Rendezvous Using a Nasobiliary Drainage Tube

Tomohiro Yamazaki iD, Kenji Nakamura iD, Yuichiro Suzuki, Yuntae Kim, Shuhei Okuyama, Koichi Takagi, Katsuyuki Fukuda

DEN Open · 2026-04 · 6 (1)

DOI: 10.1002/deo2.70237 ↗

Kurz gefasst

Fachartikel in der Zeitschrift DEN Open, online erschienen am 02.11.2025. Verfasst von Tomohiro Yamazaki und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology St. Luke's International Hospital Tokyo Japan. Die Arbeit nennt 10 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Endoscopic ultrasound‐guided rendezvous (EUS‐RV) is an alternative technique for patients in whom selective bile duct cannulation (SBDC) has failed during endoscopic retrograde cholangiopancreatography (ERCP). However, EUS‐RV has several challenging steps. Herein, we present a method for troubleshooting the EUS‐RV using a nasobiliary drainage tube (NBD) in a patient with a large periampullary diverticulum (PAD) and severe gastroptosis. An 80‐year‐old woman presented with nausea. Contrast‐enhanced computed tomography revealed a common bile duct (CBD) stone. Although ERCP was performed twice, the ampulla of Vater (AV) could not be identified due to the large PAD. Therefore, EUS‐RV was performed. The CBD was punctured from the descending part of the duodenum. Although a guidewire was advanced through the AV, the PAD hindered guidewire insertion to the anal side of the duodenum. During the switch to duodenoscopy, the guidewire was withdrawn due to gastroptosis. A subsequent attempt to puncture the CBD through the duodenal bulb resulted in guidewire entrapment. To manage the prolonged procedure, a 5‐French NBD was temporarily placed in the CBD. An NBD was subsequently inserted into the duodenum via the PAD using esophagogastroduodenoscopy under fluoroscopic guidance after 1 week. After switching to duodenoscopy, SBDC was successful along the NBD that was not withdrawn, and the stone was removed. NBD use in EUS‐RV may be effective in difficult cases of guidewire manipulation into the distal duodenum due to PAD and guidewire maintenance due to gastroptosis. Further, NBD is a readily available device, making its use convenient.

Schlagwörter

Stichwörter der Autor:innen

EUS‐RVendoscopic ultrasoundnasobiliary drainage tuberendezvous techniquetroubleshooting

Autor:innen und Institutionen

  • Department of Gastroenterology St. Luke's International Hospital Tokyo Japan.
  • Department of Gastroenterology Tokyo Dental College Ichikawa General Hospital Ichikawa Chiba Japan.

ORCID-Profile: Tomohiro Yamazaki, Kenji Nakamura

Zitieren

APA

Yamazaki, T., Nakamura, K., Suzuki, Y., Kim, Y., Okuyama, S., Takagi, K., & Fukuda, K. (2026). Troubleshooting of Endoscopic Ultrasound‐guided Rendezvous Using a Nasobiliary Drainage Tube. DEN Open, 6(1). https://doi.org/10.1002/deo2.70237

Vancouver

Yamazaki T, Nakamura K, Suzuki Y, Kim Y, Okuyama S, Takagi K, et al. Troubleshooting of Endoscopic Ultrasound‐guided Rendezvous Using a Nasobiliary Drainage Tube. DEN Open. 2026;6(1). doi:10.1002/deo2.70237

BibTeX
@article{Yamazaki2026,
  author = {Yamazaki, Tomohiro and Nakamura, Kenji and Suzuki, Yuichiro and Kim, Yuntae and Okuyama, Shuhei and Takagi, Koichi and Fukuda, Katsuyuki},
  title = {Troubleshooting of Endoscopic Ultrasound‐guided Rendezvous Using a Nasobiliary Drainage Tube},
  journal = {DEN Open},
  year = {2026},
  volume = {6},
  number = {1},
  doi = {10.1002/deo2.70237}
}
Kostenlos starten →