EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Adequacy evaluation of 22‐gauge needle endoscopic ultrasound‐guided tissue acquisition samples and glass slides preparation for successful comprehensive genomic profiling testing: A single institute experience

Tami Nagatani iD, Yoji Wani, Masahiro Takatani, Soichiro Fushimi, Hirofumi Inoue, Shinichiro Hori, Kyohei Kai, Hideki Yamamoto, Tetsuya Okazaki, Maki Tanioka, Hiroyuki Okada, Akira Hirasawa

DEN Open · 2026-04 · 6 (1)

DOI: 10.1002/deo2.70104 ↗

Kurz gefasst

Fachartikel in der Zeitschrift DEN Open, online erschienen am 09.05.2025. Verfasst von Tami Nagatani und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pathology Japanese Red Cross Society Himeji Red Cross Hospital Hyogo Japan. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

This study aimed to evaluate the successful sequencing rate of Foundation One CDx (F1CDx) using small tissue samples obtained with a 22‐gauge needle (22G) through endoscopic ultrasound‐guided fine needle acquisition (EUS‐TA) and to propose guidelines for tissue quantity evaluation criteria and proper slide preparation in clinical practice.

Methods

Between June 2019 and April 2024, 119 samples of 22G EUS‐TA collected for F1CDx testing at Himeji Red Cross Hospital were retrospectively reviewed. Tissue adequacy was only assessed based on tumor cell percentage (≥20%). The procedure stopped when white tissue fragments reached 20 mm during macroscopic on‐site evaluation. The specimens were prepared using both ‘tissue preserving sectioning’ to retain tissue within formalin‐fixed paraffin‐embedded blocks and the ‘thin sectioning matched needle gauge and tissue length’ method with calculation to ensure minimal unstained slides for the 1 mm 3 sample volume criterion. Tissue area from HE slides and sample volume were measured, and F1CDx reports were analyzed.

Results

Of 119 samples, 108 (90.8%) were suitable for F1CDx. Excluding the cases not submitted for testing, in the 45 cases where F1CDx was done using 22G EUS‐TA samples, eight (17.8%) had a sum of tissue area tissue of 25 mm 2 or greater in the HE‐stained sample. However, all cases met the F1CDx 1 mm 3 volume criterion by submitting > 30 unstained slides per sample. As a result, 43 of 45 cases (95.6%) were successfully analyzable.

Conclusions

The 22G EUS‐TA needle is an effective tool for providing the sufficient tissue volume required for F1CDx.

Schlagwörter

Stichwörter der Autor:innen

biliary tract cancercomprehensive genomic profilingendoscopic ultrasound‐guided fine needle aspirationendoscopic ultrasound‐guided fine needle biopsypancreatic cancer

Autor:innen und Institutionen

  • Department of Pathology Japanese Red Cross Society Himeji Red Cross Hospital Hyogo Japan.
  • Department of Genetic Medicine Japanese Red Cross Society Himeji Red Cross Hospital Hyogo Japan.
  • Clinical Genomic Medicine Dentistry and Pharmaceutical Science Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences Okayama Japan.
  • Department of Internal Medicine Japanese Red Cross Society Himeji Red Cross Hospital Hyogo Japan.
  • Division of Medical Support Dentistry and Pharmaceutical Science Okayama University Graduate School of Medicine Okayama Japan.

ORCID-Profile: Tami Nagatani

Zitieren

APA

Nagatani, T., Wani, Y., Takatani, M., Fushimi, S., Inoue, H., Hori, S., Kai, K., Yamamoto, H., Okazaki, T., Tanioka, M., Okada, H., & Hirasawa, A. (2026). Adequacy evaluation of 22‐gauge needle endoscopic ultrasound‐guided tissue acquisition samples and glass slides preparation for successful comprehensive genomic profiling testing: A single institute experience. DEN Open, 6(1). https://doi.org/10.1002/deo2.70104

Vancouver

Nagatani T, Wani Y, Takatani M, Fushimi S, Inoue H, Hori S, et al. Adequacy evaluation of 22‐gauge needle endoscopic ultrasound‐guided tissue acquisition samples and glass slides preparation for successful comprehensive genomic profiling testing: A single institute experience. DEN Open. 2026;6(1). doi:10.1002/deo2.70104

BibTeX
@article{Nagatani2026,
  author = {Nagatani, Tami and Wani, Yoji and Takatani, Masahiro and Fushimi, Soichiro and Inoue, Hirofumi and Hori, Shinichiro and Kai, Kyohei and Yamamoto, Hideki and Okazaki, Tetsuya and Tanioka, Maki and Okada, Hiroyuki and Hirasawa, Akira},
  title = {Adequacy evaluation of 22‐gauge needle endoscopic ultrasound‐guided tissue acquisition samples and glass slides preparation for successful comprehensive genomic profiling testing: A single institute experience},
  journal = {DEN Open},
  year = {2026},
  volume = {6},
  number = {1},
  doi = {10.1002/deo2.70104}
}
Kostenlos starten →