Comparison of fine‐needle aspiration and core‐needle biopsy in the pathological evaluation on thyroid lesions: A single‐center experience on 407 Chinese patients
Diagnostic Cytopathology · 2023
DOI: 10.1002/dc.25107 ↗Kurz gefasst
Fachartikel in der Zeitschrift Diagnostic Cytopathology, 2023. Verfasst von Wei Li und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pathology, Tianjin First Central Hospital, Tianjin, China. Hauptthemen laut MEDLINE: Thyroid Neoplasms, Thyroid Nodule. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 16 Literaturangaben. Gefördert von: General Financial Grant from the China Postdoctoral Science Foundation.
Abstract (Originalsprache)
Background
The object of this study was to compare the diagnosis performance of US‐guided fine‐needle aspiration (FNA) and core‐needle biopsy (CNB) for patients with thyroid nodules, in aspects of sensitivity, specificity, accuracy, positive predictive value (PPV) and negative predictive value (NPV). Materials and Methods Four hundred seven Chinese patients from July 2019 to June 2022 were retrospectively recruited in this study. Cytological diagnoses were categorized into six categories based on the 2017 Bethesda System for Reporting Thyroid Cytopathology (BSRTC), and histological specimens were drawn a diagnosis by means of an analogy with the Bethesda system.
Results
All patients incorporated were proceed with surgical excision (SE) and received final surgical diagnoses. The rate of malignancy (ROM) was comparable between two methods, with the exception that the test‐negative category of the FNA group was significantly higher than that of the CNB group (39.25% vs. 23.86%, p = .022). Sensitivity and accuracy were higher in CNB group (82.50% and 87.83%, respectively) than that in FNA group (72.00% and 79.36%, respectively), as well as NPV (76.14% in CNB vs. 60.75% in FNA), but not in terms of the specificity and PPV (95.59% and 97.30% in FNA vs. 97.10% and 98.02% in CNB).
Conclusion
CNB displayed a higher sensitivity and accuracy than FNA in malignant lesions of thyroid. Both FNA and CNB exhibit excellent performance with the understanding that both need to be applied under the most appropriate conditions to maximize their benefits.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Pathology, Tianjin First Central Hospital, Tianjin, China.
- Department of Cell Biology, School of Basic Medical Sciences, Tianjin Medical University, Tianjin, China.
- Department of Thyroid and Breast Surgery, Tianjin First Central Hospital, Tianjin, China.
ORCID-Profile: Wei Li
Förderung
- General Financial Grant from the China Postdoctoral Science Foundation
Zitieren
APA
Li, W., Han, Y. T., Hu, Z., Zhang, Y., Zhao, X., Guo, X., Cai, W., & Zhang, M. (2023). Comparison of fine‐needle aspiration and core‐needle biopsy in the pathological evaluation on thyroid lesions: A single‐center experience on 407 Chinese patients. Diagnostic Cytopathology. https://doi.org/10.1002/dc.25107
Vancouver
Li W, Han YT, Hu Z, Zhang Y, Zhao X, Guo X, et al. Comparison of fine‐needle aspiration and core‐needle biopsy in the pathological evaluation on thyroid lesions: A single‐center experience on 407 Chinese patients. Diagnostic Cytopathology. 2023. doi:10.1002/dc.25107
BibTeX
@article{Li2023,
author = {Li, Wei and Han, Ya-Ting and Hu, Zhandong and Zhang, Yujie and Zhao, Xin and Guo, Xuexi and Cai, Wenjuan and Zhang, Mingfang},
title = {Comparison of fine‐needle aspiration and core‐needle biopsy in the pathological evaluation on thyroid lesions: A single‐center experience on 407 Chinese patients},
journal = {Diagnostic Cytopathology},
year = {2023},
doi = {10.1002/dc.25107}
}
EUVIMED