Superior Intracellular Detection of Cytokines, Transcription Factors, and Phosphoproteins by CyTOF Compared With Fluorescent Cytometry
Cytometry Part A · 2026-03 · 109 (3) · 167-179
DOI: 10.1002/cytoa.70011 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Cytometry Part A, online erschienen am 09.03.2026. Verfasst von Michael J Cohen und 10 weiteren Autor:innen. Beteiligte Einrichtung: Standard BioTools Canada, Markham, Ontario, Canada. Hauptthemen laut MEDLINE: Flow Cytometry, Cytokines, Phosphoproteins, Transcription Factors. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIH HHS, Standard Biotools, National Institutes of Health.
Abstract (Originalsprache)
Unraveling biological complexity, such as immune subset distribution in infectious disease(s), autoimmunity, or tumor heterogeneity, requires technologies capable of single‐cell proteomic analysis such as flow cytometry. Surface phenotyping alone is often insufficient, as interrogating functional capacity is required to determine cellular mechanisms and effectively inform diagnostic biomarker discovery as well as development of novel therapeutics and vaccines. However, large flow panels with intracellular markers are subject to numerous challenges, including spectral overlap and background cellular autofluorescence, reducing resolving power for rare subsets or populations defined by low‐abundance expression. We posited that use of mass cytometry may overcome such limitations; to address this, three small (10–12‐plex) clone‐matched antibody panels were evaluated by spectral flow and mass cytometry. Panels were comprised of surface and intracellular targets (phospho‐epitopes, transcription factors or cytokines) and designed to minimize fluorescence spectral overlap. Overall, CyTOF technology demonstrated superior signal resolution compared with fluorescent counterparts for all three types of the intracellular targets that were compared. There was clear stimulation‐specific resolution of IL‐10 and IL‐13 cytokine‐producing cells from using mass cytometry that was not seen in the fluorescent panel and is not routinely detectable using that platform. Thus, accurate detection of immune cells with distinct functional signatures was enabled, permitting more unique and understudied populations to be quantified, including T regulatory 1 (Tr1) and cytotoxic type 2 (Tc2) T cell subsets. These results indicate that CyTOF technology has a unique ability to provide a high‐resolution, comprehensive picture of the immuno‐diversity present in a sample. Therefore, we posit that a new focus on use of mass cytometry for intracellular readouts could catalyze seminal discoveries in functional immune profiling, driving therapeutic design and diagnostics.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Standard BioTools Canada, Markham, Ontario, Canada.
- Department of Virology, Immunology, and Microbiology, Boston University Chobanian & Avedisian School of Medicine, Boston, Massachusetts, USA.
- Department of Pathology & Laboratory Medicine, Boston University Chobanian & Avedisian School of Medicine, Boston, Massachusetts, USA.
- Flow Cytometry Core Facility, Boston University Chobanian & Avedisian School of Medicine, Boston, Massachusetts, USA.
- Pulmonary Center, Boston University Chobanian & Avedisian School of Medicine, Boston, Massachusetts, USA.
ORCID-Profile: Anna C Belkina
Förderung
- NIH HHS
- Standard Biotools
- National Institutes of Health
Zitieren
APA
Cohen, M. J., Smith-Mahoney, E. L., Bailey, M., Wang, L., Tracey, L. J., Polanco, L., King, D., Loh, C., Cappione, A. J., Belkina, A. C., & Snyder-Cappione, J. E. (2026). Superior Intracellular Detection of Cytokines, Transcription Factors, and Phosphoproteins by CyTOF Compared With Fluorescent Cytometry. Cytometry Part A, 109(3), 167-179. https://doi.org/10.1002/cytoa.70011
Vancouver
Cohen MJ, Smith-Mahoney EL, Bailey M, Wang L, Tracey LJ, Polanco L, et al. Superior Intracellular Detection of Cytokines, Transcription Factors, and Phosphoproteins by CyTOF Compared With Fluorescent Cytometry. Cytometry Part A. 2026;109(3):167-179. doi:10.1002/cytoa.70011
BibTeX
@article{Cohen2026,
author = {Cohen, Michael J and Smith-Mahoney, Erika L and Bailey, Madison and Wang, Ling and Tracey, Lauren J and Polanco, Laura and King, David and Loh, Christina and Cappione, Amedeo J and Belkina, Anna C and Snyder-Cappione, Jennifer E},
title = {Superior Intracellular Detection of Cytokines, Transcription Factors, and Phosphoproteins by CyTOF Compared With Fluorescent Cytometry},
journal = {Cytometry Part A},
year = {2026},
volume = {109},
number = {3},
pages = {167--179},
doi = {10.1002/cytoa.70011}
}
EUVIMED