Fachartikel in der Zeitschrift Cytometry Part B: Clinical Cytometry, 2025. Verfasst von Jean Oak und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pathology, Stanford University, Stanford, California, USA. Hauptthemen laut MEDLINE: Flow Cytometry, Clinical Laboratory Information Systems, Pathology, Clinical. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 23 Literaturangaben.
Abstract (Originalsprache)
Implementing a new laboratory information system (LIS) presents an opportunity to improve operational efficiency and streamline reporting by refining workflows by utilizing LIS functionality. Flow cytometry laboratories face unique challenges because the specimen and test results may be categorized under clinical pathology (CP), anatomic pathology (AP), or both. We describe the design and implementation of reporting flow cytometry results within the Epic Beaker CP module, its interface with the Epic Beaker AP module, and integrated reporting for AP/CP cases at an academic institution. This manuscript emphasizes the challenges and steps needed to integrate anatomic and clinical pathology workflows by leveraging LIS functionality to implement electronic and predominantly paperless workflows within a flow cytometry laboratory.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Pathology, Stanford University, Stanford, California, USA.
- Flow Cytometry Laboratory, Stanford Health Care, Stanford, California, USA.
- Flow Cytometry Laboratory, Stanford Health Care, Laboratory Systems & Services, Stanford, California, USA.
ORCID-Profile: Jean Oak
Zitieren
APA
Oak, J., Gitana, G., Wei, S., Parry, M., & Tan, B. (2025). Implementation of beaker CP for flow cytometry: Workflow optimization and integration at Stanford Health Care. Cytometry Part B: Clinical Cytometry. https://doi.org/10.1002/cyto.b.22223
Vancouver
Oak J, Gitana G, Wei S, Parry M, Tan B. Implementation of beaker CP for flow cytometry: Workflow optimization and integration at Stanford Health Care. Cytometry Part B: Clinical Cytometry. 2025. doi:10.1002/cyto.b.22223
BibTeX
@article{Oak2025,
author = {Oak, Jean and Gitana, Gary and Wei, Sibing and Parry, Melissa and Tan, Brent},
title = {Implementation of beaker CP for flow cytometry: Workflow optimization and integration at Stanford Health Care},
journal = {Cytometry Part B: Clinical Cytometry},
year = {2025},
doi = {10.1002/cyto.b.22223}
}
EUVIMED