EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Spectral, Semi‐Spectral, and Bandwidth Flow Cytometric Implementation of Multiplex Cytokine Bead Assays

Jacob Laster, Jenny Hernandez-Davies, D Huw Davies, Egest J Pone iD

Cytometry Part A · 2026

DOI: 10.1002/cyto.a.70057 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cytometry Part A, 2026. Verfasst von Jacob Laster und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physiology & Biophysics, Vaccine Research & Development Center, School of Medicine, University of California, Irvine, Irvine, Californi…. Hauptthemen laut MEDLINE: Flow Cytometry, Cytokines. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: NIH HHS, U.S. Department of Defense, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Multiplex cytokine bead assays (MCBA) have previously been carried out on conventional (aka classical, or bandwidth) flow cytometers, and issues involving unmixing distortions were encountered when using the manufacturer's set‐up beads for unmixing full‐spectrum data. After resolving such issues, we introduce and characterize the first full‐spectrum flow cytometry implementation of MCBAs. In more detail, the set‐up beads were originally produced for conventional cytometers, and a temporary work‐around was issued for the semi‐spectral mode only: spectral acquisition but bandwidth data display and analysis. We proceeded to make our own reference fluorophore controls (RFCs), starting with polystyrene beads derivatized with carboxyl functional groups that were first conjugated with streptavidin and then titrated with PE‐biotin. The autofluorescence profile of the in‐house conjugated PE beads matched that of the kit beads, and proper use of PE and “APC” RFCs enabled normal spectral unmixing without any distortions. Comparison of the three modes, namely spectral, semi‐spectral, and bandwidth, illustrated the advantages of the spectral mode, including precision and resolution. In addition to enabling proper spectral implementation of the MCBA, a full‐spectrum approach opens the door for various types of more complex multi‐analyte bead assays yielding richer information, which have previously remained out of reach in conventional cytometry.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Flow CytometryCytokinesHumansMicrospheresPolystyrenesFluorescent DyesStreptavidin

Substanzen

CytokinesPolystyrenesFluorescent DyesStreptavidin

Autor:innen und Institutionen

  • Department of Physiology & Biophysics, Vaccine Research & Development Center, School of Medicine, University of California, Irvine, Irvine, California, USA.

ORCID-Profile: Egest J Pone

Förderung

  • NIH HHS
  • U.S. Department of Defense
  • National Institutes of Health

Zitieren

APA

Laster, J., Hernandez-Davies, J., Davies, D. H., & Pone, E. J. (2026). Spectral, Semi‐Spectral, and Bandwidth Flow Cytometric Implementation of Multiplex Cytokine Bead Assays. Cytometry Part A. https://doi.org/10.1002/cyto.a.70057

Vancouver

Laster J, Hernandez-Davies J, Davies DH, Pone EJ. Spectral, Semi‐Spectral, and Bandwidth Flow Cytometric Implementation of Multiplex Cytokine Bead Assays. Cytometry Part A. 2026. doi:10.1002/cyto.a.70057

BibTeX
@article{Laster2026,
  author = {Laster, Jacob and Hernandez-Davies, Jenny and Davies, D Huw and Pone, Egest J},
  title = {Spectral, Semi‐Spectral, and Bandwidth Flow Cytometric Implementation of Multiplex Cytokine Bead Assays},
  journal = {Cytometry Part A},
  year = {2026},
  doi = {10.1002/cyto.a.70057}
}
Kostenlos starten →