Fachartikel in der Zeitschrift Cytometry Part A, 2026. Verfasst von Alexander Putz und 2 weiteren Autor:innen. Beteiligte Einrichtung: Physikalisch-Technische Bundesanstalt (PTB), Berlin, Germany. Hauptthemen laut MEDLINE: Flow Cytometry. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Federal Ministry for Economic Affairs and Energy, Bundesministerium für Wirtschaft und Energie.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Flow cytometers, based on an optical measurement principle, are widely used for cell characterization in a variety of medical applications. Especially in hematology, high counting accuracy is crucial. Therefore, it is essential to develop accurate but also fast coincidence correction methods. We developed a procedure for post‐processing the time‐dependent signals (pulses) captured by the detectors during the transition of particles or cells through the flow cytometer's laser beam. These pulses are characterized by their area, maximum intensity, standard deviation, and skewness. By using standard deviation versus area, we are able to detect significantly more coincidences in monodisperse suspensions than by using the common method of area or width versus height. This demonstrates the superior sensitivity and accuracy of our approach for coincidence detection. In polydisperse suspensions and whole blood, we successfully identify and distinguish coincidences between differently sized particles (e.g., 1 and 5 μm) and particles of the same size, as well as between thrombocytes and erythrocytes based on pulse skewness and standard deviation. Unlike the current state‐of‐the‐art method for coincidence correction in cell concentration measurements, which relies on statistical evaluation through dilution series, the developed procedure identifies a specific number of coincidences for individual measurements.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Flow CytometrySuspensionsHumansErythrocytesBlood PlateletsParticle Size

Stichwörter der Autor:innen

agglomeratescoincidence detectiondoubletslabel‐freepolydisperse suspensionspostprocessingpulse‐shape analysis

Substanzen

Suspensions

Autor:innen und Institutionen

  • Physikalisch-Technische Bundesanstalt (PTB), Berlin, Germany.

ORCID-Profile: Alexander Putz, Jonas Gienger, Martin Hussels

Förderung

  • Federal Ministry for Economic Affairs and Energy
  • Bundesministerium für Wirtschaft und Energie

Zitieren

APA

Putz, A., Gienger, J., & Hussels, M. (2026). Coincidence Detection in Flow Cytometry Using Pulse‐Shape Analysis in Polydisperse Suspensions. Cytometry Part A. https://doi.org/10.1002/cyto.a.70053

Vancouver

Putz A, Gienger J, Hussels M. Coincidence Detection in Flow Cytometry Using Pulse‐Shape Analysis in Polydisperse Suspensions. Cytometry Part A. 2026. doi:10.1002/cyto.a.70053

BibTeX
@article{Putz2026,
  author = {Putz, Alexander and Gienger, Jonas and Hussels, Martin},
  title = {Coincidence Detection in Flow Cytometry Using Pulse‐Shape Analysis in Polydisperse Suspensions},
  journal = {Cytometry Part A},
  year = {2026},
  doi = {10.1002/cyto.a.70053}
}
Kostenlos starten →