EUVIMEDEUVIMED entdecken
Crossref

A Modular High‐Parameter Flow Cytometry Framework: Pre‐Analytical Optimization and Validation for Clinical Research

Jennifer Scott, Iva Lelios, Tobias Rutishauser, Stefan Ganter, Megan M McCausland, Karen Smith, Alistair Watt, Enrique Gómez iD

Cytometry Part A · 2026

DOI: 10.1002/cyto.a.70049 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cytometry Part A, 2026. Verfasst von Jennifer Scott und 7 weiteren Autor:innen. Beteiligte Einrichtung: Translational Science Department, IQVIA Laboratories, Livingstone, UK. Hauptthemen laut MEDLINE: Flow Cytometry, Immunophenotyping. Die Arbeit nennt 50 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

High‐parameter flow cytometry (hpFCM) enables powerful immune profiling and biomarker discovery in clinical trials. However, its clinical adoption is hindered by assay variability, logistical challenges, and technical complexity. Ensuring data reproducibility and robustness requires stringent quality controls and standardized validation. We introduce a new concept for implementing hpFCM in drug development, a modular hpFCM approach. It features a 12‐marker core panel with 21 additional markers distributed in five interchangeable modules, enabling flexible assay customization throughout clinical studies. This innovative design allows for dynamic modifications during clinical development, facilitating evolving immunophenotyping of T and NK cells and comprehensive biomarker analysis. Validation in accordance with CLSI H62 guidelines confirmed the assay's reliability across exploratory and secondary endpoints, demonstrating high accuracy, selectivity, repeatability, and reproducibility independent of the applied assay configuration. Key secondary endpoints, including CD8+ cytotoxic and regulatory T cells, achieved precision, with repeatability and inter‐operator variability under 20% coefficient of variation (CV), while specimen stability was maintained over 4 days of ambient storage. For exploratory endpoints, 90% of analytes met repeatability criteria, with 55% remaining stable over 4 days. The modular approach enhances end‐to‐end solutions and assay adaptability, supporting both targeted and exploratory strategies for clinical biomarker analysis. Importantly, robust performance and data comparability among different assay configurations were confirmed in both whole blood and frozen PBMC samples. By addressing key limitations in current hpFCM workflows, this modular approach provides a scalable, agile, and cost‐effective framework designed to support biomarker strategies during drug development. This framework was conceptualized to increase operational efficiency and enable reverse translational approaches by allowing the rapid integration of emerging markers. Consequently, this design facilitates dynamic immunophenotyping and biomarker discovery, streamlining the path from exploratory research to clinical implementation. Importantly, while the assay is designed for biomarker discovery and exploratory immune monitoring in clinical trials, its clinical utility, therapeutic‐response performance, and feasibility in multi‐site real‐world trial logistics remain to be established in ongoing studies involving specific disease cohorts.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Flow CytometryImmunophenotypingHumansReproducibility of ResultsBiomarkersBiomedical ResearchKiller Cells, NaturalDrug Development

Stichwörter der Autor:innen

biomarkersclinical cytometrycontext of usehigh‐parameter flow cytometry assaymodular assayvalidation

Substanzen

Biomarkers

Autor:innen und Institutionen

  • Translational Science Department, IQVIA Laboratories, Livingstone, UK.
  • Roche Pharma Research and Early Development, Roche Innovation Center Basel, Basel, Switzerland.
  • Translational Science Department, IQVIA Laboratories, Atlanta, USA.

ORCID-Profile: Enrique Gómez

Zitieren

APA

Scott, J., Lelios, I., Rutishauser, T., Ganter, S., McCausland, M. M., Smith, K., Watt, A., & Gómez, E. (2026). A Modular High‐Parameter Flow Cytometry Framework: Pre‐Analytical Optimization and Validation for Clinical Research. Cytometry Part A. https://doi.org/10.1002/cyto.a.70049

Vancouver

Scott J, Lelios I, Rutishauser T, Ganter S, McCausland MM, Smith K, et al. A Modular High‐Parameter Flow Cytometry Framework: Pre‐Analytical Optimization and Validation for Clinical Research. Cytometry Part A. 2026. doi:10.1002/cyto.a.70049

BibTeX
@article{Scott2026,
  author = {Scott, Jennifer and Lelios, Iva and Rutishauser, Tobias and Ganter, Stefan and McCausland, Megan M and Smith, Karen and Watt, Alistair and Gómez, Enrique},
  title = {A Modular High‐Parameter Flow Cytometry Framework: Pre‐Analytical Optimization and Validation for Clinical Research},
  journal = {Cytometry Part A},
  year = {2026},
  doi = {10.1002/cyto.a.70049}
}
Kostenlos starten →