EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Fluorescent Cell Barcoding of Peripheral Blood Mononuclear Cells for High‐Throughput Assessment of Vaccine‐Induced T Cell Responses in Low‐Volume Research Samples

Janna R Shapiro iD, Nathalie Simard, Shelly Bolotin, Tania H Watts

Cytometry Part A · 2025-05 · 107 (5) · 321-332

DOI: 10.1002/cyto.a.24933 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cytometry Part A, online erschienen am 09.04.2025. Verfasst von Janna R Shapiro und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Immunology, Temerty Faculty of Medicine, The University of Toronto, Toronto, Ontario, Canada. Hauptthemen laut MEDLINE: Leukocytes, Mononuclear, T-Lymphocytes, Flow Cytometry, High-Throughput Screening Assays. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Donation from Juan and Stefania Speck, Canadian Immunization Research Network, CIHR.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

T cell responses are rarely measured in large‐scale human vaccine studies due to the sample volumes required, as well as the logistical, technical, and financial challenges associated with available assays. Fluorescent cell barcoding has been proposed in other contexts to allow for more high‐throughput flow cytometry‐based assays. Here, we aimed to expand on existing barcoding approaches to develop a reagent and sample‐sparing assay for in‐depth assessment of T cell responses to vaccine antigens. By using various concentrations of two fixable viability dyes in a matrix format, up to 25 samples that were pooled and acquired together could be successfully deconvoluted based on their unique fluorescent signature. This fluorescent cell barcoding approach was then combined with extracellular and intracellular staining to identify functional (i.e., producing at least one cytokine) and polyfunctional (i.e., producing multiple cytokines) T cells in response to vaccine antigen stimulation. As a proof‐of‐concept, we plated just 200,000 peripheral blood mononuclear cells (PBMC) per condition, and by staining and acquiring only two pooled samples, we were able to detect rare antigen‐specific T cell responses in eight donors to four stimulants each. The frequencies of antigen‐induced cytokine‐positive cells detected in barcoded samples with 200,000 input PBMC were strongly correlated with those detected in non‐barcoded samples from the same donors with 1 million input PBMC, demonstrating the validity of this approach. In conclusion, by reducing the number of PBMC needed by five‐fold, and the volume of staining reagents needed by 25‐fold, this assay has widespread potential applications to human vaccine studies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Leukocytes, MononuclearT-LymphocytesFlow CytometryHigh-Throughput Screening AssaysVaccinesHumansFluorescent DyesCytokinesStaining and Labeling

Stichwörter der Autor:innen

T cell responsesfixable viability dyesflow cytometryfluorescent cell barcodingperipheral blood mononuclear cellspolyfunctional T cellsvaccinology

Substanzen

VaccinesFluorescent DyesCytokines

Autor:innen und Institutionen

  • Department of Immunology, Temerty Faculty of Medicine, The University of Toronto, Toronto, Ontario, Canada.
  • The Center for Vaccine Preventable Diseases, Dalla Lana School of Public Health, The University of Toronto, Toronto, Ontario, Canada.
  • Public Health Ontario, Toronto, Ontario, Canada.
  • Department of Laboratory Medicine and Pathobiology, Temerty Faculty of Medicine, The University of Toronto, Toronto, Ontario, Canada.

ORCID-Profile: Janna R Shapiro

Förderung

  • Donation from Juan and Stefania Speck
  • Canadian Immunization Research Network
  • CIHR
  • Canadian Institutes of Health Research

Zitieren

APA

Shapiro, J. R., Simard, N., Bolotin, S., & Watts, T. H. (2025). Fluorescent Cell Barcoding of Peripheral Blood Mononuclear Cells for High‐Throughput Assessment of Vaccine‐Induced T Cell Responses in Low‐Volume Research Samples. Cytometry Part A, 107(5), 321-332. https://doi.org/10.1002/cyto.a.24933

Vancouver

Shapiro JR, Simard N, Bolotin S, Watts TH. Fluorescent Cell Barcoding of Peripheral Blood Mononuclear Cells for High‐Throughput Assessment of Vaccine‐Induced T Cell Responses in Low‐Volume Research Samples. Cytometry Part A. 2025;107(5):321-332. doi:10.1002/cyto.a.24933

BibTeX
@article{Shapiro2025,
  author = {Shapiro, Janna R and Simard, Nathalie and Bolotin, Shelly and Watts, Tania H},
  title = {Fluorescent Cell Barcoding of Peripheral Blood Mononuclear Cells for High‐Throughput Assessment of Vaccine‐Induced T Cell Responses in Low‐Volume Research Samples},
  journal = {Cytometry Part A},
  year = {2025},
  volume = {107},
  number = {5},
  pages = {321--332},
  doi = {10.1002/cyto.a.24933}
}
Kostenlos starten →