EUVIMEDEUVIMED entdecken
Open Access

Highly Efficient Calibration‐Free Color Compensation Algorithm for Imaging Flow Cytometry

Ziqi Zhou iD, Zhaoyu Lai, Rui Tang, Xinyu Chen, Yunjia Qu, Lin Xia, Micayla George, Adonary Munoz, Minhong Zhou, Yu-Chen Tai, Yingxiao Wang, Hu Cang und 1 weitere

Cytometry Part A · 2025

DOI: 10.1002/cyto.a.24931 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cytometry Part A, 2025. Verfasst von Ziqi Zhou und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical and Computer Engineering, University of California San Diego, La Jolla, California, USA. Hauptthemen laut MEDLINE: Flow Cytometry, Algorithms, Image Processing, Computer-Assisted. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIDA NIH HHS, NIGMS NIH HHS, NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

As an emerging platform gaining significant attention from the biomedical community, multiplexed fluorescent imaging from imaging flow cytometry enables simultaneous detection of numerous biological targets within a single cell. Due to the spectral overlap, signals from one fluorophore can bleed into other detection channels, leading to spillover artifacts, which cause erroneous results and false discoveries. Existing color compensation algorithms use special samples to calibrate the fluorophores individually, a time‐consuming and laborious process that is cumbersome and hard to scale. While recent developments in calibration‐free algorithms produce promising results in multi‐color microscope images, these algorithms, when applied to single‐cell images with all the fluorophores within a small and constrained area, tend to cause overcorrection by treating real signals as crosstalk and triggering stability problems during the iterative computation process. Here we demonstrate a simple and intuitive algorithm that greatly reduces overcorrection and is computationally efficient. While designed for imaging flow cytometers, our calibration‐free crosstalk removal algorithm can be readily applied to microscopy as well. We have validated its effectiveness on various datasets, including simulated cell images, 2D and 3D imaging flow cytometry images, and microscopic images. Our algorithm offers an effective solution for multi‐parameter single‐cell images where channels are often both spectrally and spatially overlapped within the limited area of a single cell.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Flow CytometryAlgorithmsImage Processing, Computer-AssistedCalibrationHumansColorFluorescent DyesSingle-Cell AnalysisMicroscopy, Fluorescence

Stichwörter der Autor:innen

color compensationimaging flow cytometrymulti‐fluorescence cell images

Substanzen

Fluorescent Dyes

Autor:innen und Institutionen

  • Department of Electrical and Computer Engineering, University of California San Diego, La Jolla, California, USA.
  • NanoCellect Biomedical Inc., San Diego, California, USA.
  • Department of Bioengineering, University of California San Diego, La Jolla, California, USA.
  • Institute of Engineering in Medicine, University of California San Diego, La Jolla, California, USA.
  • Alfred E. Mann Department of Biomedical Engineering, University of Southern California, Los Angeles, California, USA.
  • Department of Developmental and Cell Biology, University of California Irvine, Irvine, California, USA.

ORCID-Profile: Ziqi Zhou

Förderung

  • NIDA NIH HHS
  • NIGMS NIH HHS
  • NIH HHS
  • National Science Foundation
  • National Institutes of Health

Zitieren

APA

Zhou, Z., Lai, Z., Tang, R., Chen, X., Qu, Y., Xia, L., George, M., Munoz, A., Zhou, M., Tai, Y. C., Wang, Y., Cang, H., & Lo, Y. H. (2025). Highly Efficient Calibration‐Free Color Compensation Algorithm for Imaging Flow Cytometry. Cytometry Part A. https://doi.org/10.1002/cyto.a.24931

Vancouver

Zhou Z, Lai Z, Tang R, Chen X, Qu Y, Xia L, et al. Highly Efficient Calibration‐Free Color Compensation Algorithm for Imaging Flow Cytometry. Cytometry Part A. 2025. doi:10.1002/cyto.a.24931

BibTeX
@article{Zhou2025,
  author = {Zhou, Ziqi and Lai, Zhaoyu and Tang, Rui and Chen, Xinyu and Qu, Yunjia and Xia, Lin and George, Micayla and Munoz, Adonary and Zhou, Minhong and Tai, Yu-Chen and Wang, Yingxiao and Cang, Hu and Lo, Yu-Hwa},
  title = {Highly Efficient Calibration‐Free Color Compensation Algorithm for Imaging Flow Cytometry},
  journal = {Cytometry Part A},
  year = {2025},
  doi = {10.1002/cyto.a.24931}
}
Kostenlos starten →