The challenge of standardizing CAR‐T cell monitoring: A comparison of two flow‐cytometry methods and correlation with qPCR technique
Cytometry Part A · 2024
DOI: 10.1002/cyto.a.24825 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Cytometry Part A, 2024. Verfasst von Juan Luis Valdivieso-Shephard und 8 weiteren Autor:innen. Beteiligte Einrichtung: Immunology Department, La Paz University Hospital, Madrid, Spain. Hauptthemen laut MEDLINE: Flow Cytometry, Immunotherapy, Adoptive, HIV-1, Viral Load. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 14 Literaturangaben.
Abstract (Originalsprache)
Chimeric antigen receptor (CAR) T‐cell therapy is a breakthrough in hematologic malignancies, such as acute B lymphoblastic leukemia (B‐ALL). Monitoring this treatment is recommended, although standardized protocols have not been developed yet. This work compares two flow cytometry monitoring strategies and correlates this technique with qPCR method. CAR‐T cells were detected by two different flow‐cytometry protocols (A and B) in nine blood samples from one healthy donor and five B‐ALL patients treated with Tisagenlecleucel (Kymriah®, USA). HIV‐1 viral load allowed CAR detection by qPCR, using samples from seven healthy donors and nine B‐ALL patients. CAR detection by protocol A and B did not yield statistically significant differences (1.9% vs. 11.8% CD3 + CAR+, p = 0.07). However, protocol B showed a better discrimination of the CD3 + CAR+ population. A strong correlation was observed between protocol B and qPCR ( r = 0.7, p < 0.0001). CD3 + CAR+ cells were detected by flow cytometry only when HIV‐1 viral load was above 10 4 copies/mL. In conclusion, protocol B was the most specific flow‐cytometry procedure for the identification of CAR‐T cells and showed a high correlation with qPCR. Further efforts are needed to achieve a standardized monitoring approach.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Immunology Department, La Paz University Hospital, Madrid, Spain.
- Infectious Diseases Unit, La Paz University Hospital, Madrid, Spain.
- Advanced Therapy Medicinal Products Production Unit, Haemato-Oncology Service, La Paz University Hospital, Madrid, Spain.
- Translational Research Unit in Paediatric Haemato-Oncology, Hematopoietic Stem Cell Transplantation and Cell Therapy, La Paz University Hospital, Madrid, Spain.
- Paediatric Haemato-Oncology Department, La Paz University Hospital, Madrid, Spain.
- CIBERER U767, Center for Biomedical Network Research on Rare Diseases, Madrid, Spain.
ORCID-Profile: Ana Martínez-Feito, Elena Sánchez-Zapardiel
Zitieren
APA
Valdivieso-Shephard, J. L., Matas-Pérez, E., García-Bujalance, S., Mirones-Aguilar, I., González-Martínez, B., Pérez-Martínez, A., López-Granados, E., Martínez-Feito, A., & Sánchez-Zapardiel, E. (2024). The challenge of standardizing CAR‐T cell monitoring: A comparison of two flow‐cytometry methods and correlation with qPCR technique. Cytometry Part A. https://doi.org/10.1002/cyto.a.24825
Vancouver
Valdivieso-Shephard JL, Matas-Pérez E, García-Bujalance S, Mirones-Aguilar I, González-Martínez B, Pérez-Martínez A, et al. The challenge of standardizing CAR‐T cell monitoring: A comparison of two flow‐cytometry methods and correlation with qPCR technique. Cytometry Part A. 2024. doi:10.1002/cyto.a.24825
BibTeX
@article{ValdiviesoShephard2024,
author = {Valdivieso-Shephard, Juan Luis and Matas-Pérez, Elisabet and García-Bujalance, Silvia and Mirones-Aguilar, Isabel and González-Martínez, Berta and Pérez-Martínez, Antonio and López-Granados, Eduardo and Martínez-Feito, Ana and Sánchez-Zapardiel, Elena},
title = {The challenge of standardizing CAR‐T cell monitoring: A comparison of two flow‐cytometry methods and correlation with qPCR technique},
journal = {Cytometry Part A},
year = {2024},
doi = {10.1002/cyto.a.24825}
}
EUVIMED