EUVIMEDEUVIMED entdecken
Vergleichsstudie

The challenge of standardizing CAR‐T cell monitoring: A comparison of two flow‐cytometry methods and correlation with qPCR technique

Juan Luis Valdivieso-Shephard, Elisabet Matas-Pérez, Silvia García-Bujalance, Isabel Mirones-Aguilar, Berta González-Martínez, Antonio Pérez-Martínez, Eduardo López-Granados, Ana Martínez-Feito iD, Elena Sánchez-Zapardiel iD

Cytometry Part A · 2024

DOI: 10.1002/cyto.a.24825 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Cytometry Part A, 2024. Verfasst von Juan Luis Valdivieso-Shephard und 8 weiteren Autor:innen. Beteiligte Einrichtung: Immunology Department, La Paz University Hospital, Madrid, Spain. Hauptthemen laut MEDLINE: Flow Cytometry, Immunotherapy, Adoptive, HIV-1, Viral Load. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 14 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Chimeric antigen receptor (CAR) T‐cell therapy is a breakthrough in hematologic malignancies, such as acute B lymphoblastic leukemia (B‐ALL). Monitoring this treatment is recommended, although standardized protocols have not been developed yet. This work compares two flow cytometry monitoring strategies and correlates this technique with qPCR method. CAR‐T cells were detected by two different flow‐cytometry protocols (A and B) in nine blood samples from one healthy donor and five B‐ALL patients treated with Tisagenlecleucel (Kymriah®, USA). HIV‐1 viral load allowed CAR detection by qPCR, using samples from seven healthy donors and nine B‐ALL patients. CAR detection by protocol A and B did not yield statistically significant differences (1.9% vs. 11.8% CD3 + CAR+, p = 0.07). However, protocol B showed a better discrimination of the CD3 + CAR+ population. A strong correlation was observed between protocol B and qPCR ( r = 0.7, p < 0.0001). CD3 + CAR+ cells were detected by flow cytometry only when HIV‐1 viral load was above 10 4 copies/mL. In conclusion, protocol B was the most specific flow‐cytometry procedure for the identification of CAR‐T cells and showed a high correlation with qPCR. Further efforts are needed to achieve a standardized monitoring approach.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Flow CytometryImmunotherapy, AdoptiveHIV-1Viral LoadReceptors, Chimeric AntigenT-LymphocytesHumansReal-Time Polymerase Chain ReactionCD3 ComplexReceptors, Antigen, T-CellPrecursor Cell Lymphoblastic Leukemia-Lymphoma

Stichwörter der Autor:innen

CAR‐T therapyflow cytometrymonitoringqPCR

Substanzen

Receptors, Chimeric AntigenCD3 ComplexReceptors, Antigen, T-Cell

Autor:innen und Institutionen

  • Immunology Department, La Paz University Hospital, Madrid, Spain.
  • Infectious Diseases Unit, La Paz University Hospital, Madrid, Spain.
  • Advanced Therapy Medicinal Products Production Unit, Haemato-Oncology Service, La Paz University Hospital, Madrid, Spain.
  • Translational Research Unit in Paediatric Haemato-Oncology, Hematopoietic Stem Cell Transplantation and Cell Therapy, La Paz University Hospital, Madrid, Spain.
  • Paediatric Haemato-Oncology Department, La Paz University Hospital, Madrid, Spain.
  • CIBERER U767, Center for Biomedical Network Research on Rare Diseases, Madrid, Spain.

ORCID-Profile: Ana Martínez-Feito, Elena Sánchez-Zapardiel

Zitieren

APA

Valdivieso-Shephard, J. L., Matas-Pérez, E., García-Bujalance, S., Mirones-Aguilar, I., González-Martínez, B., Pérez-Martínez, A., López-Granados, E., Martínez-Feito, A., & Sánchez-Zapardiel, E. (2024). The challenge of standardizing CAR‐T cell monitoring: A comparison of two flow‐cytometry methods and correlation with qPCR technique. Cytometry Part A. https://doi.org/10.1002/cyto.a.24825

Vancouver

Valdivieso-Shephard JL, Matas-Pérez E, García-Bujalance S, Mirones-Aguilar I, González-Martínez B, Pérez-Martínez A, et al. The challenge of standardizing CAR‐T cell monitoring: A comparison of two flow‐cytometry methods and correlation with qPCR technique. Cytometry Part A. 2024. doi:10.1002/cyto.a.24825

BibTeX
@article{ValdiviesoShephard2024,
  author = {Valdivieso-Shephard, Juan Luis and Matas-Pérez, Elisabet and García-Bujalance, Silvia and Mirones-Aguilar, Isabel and González-Martínez, Berta and Pérez-Martínez, Antonio and López-Granados, Eduardo and Martínez-Feito, Ana and Sánchez-Zapardiel, Elena},
  title = {The challenge of standardizing CAR‐T cell monitoring: A comparison of two flow‐cytometry methods and correlation with qPCR technique},
  journal = {Cytometry Part A},
  year = {2024},
  doi = {10.1002/cyto.a.24825}
}
Kostenlos starten →