flowSim : Near duplicate detection for flow cytometry data
Cytometry Part A · 2023-11 · 103 (11) · 889-901
DOI: 10.1002/cyto.a.24776 ↗Kurz gefasst
Fachartikel in der Zeitschrift Cytometry Part A, online erschienen am 29.08.2023. Verfasst von Sebastiano Montante und 2 weiteren Autor:innen. Beteiligte Einrichtung: Terry Fox Laboratory, BC Cancer Research, Vancouver, British Columbia, Canada. Hauptthemen laut MEDLINE: Algorithms, Machine Learning. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: NIBIB NIH HHS, NIAID NIH HHS, National Institutes of Health.
Abstract (Originalsprache)
The analysis of large amounts of data is important for the development of machine learning (ML) models. flowSim is the first algorithm designed to visualize, detect and remove highly redundant information in flow cytometry (FCM) training sets to decrease the computational time for training and increase the performance of ML algorithms by reducing overfitting. flowSim performs near duplicate image detection by combining community detection algorithms with the density analysis of the marker expression values. flowSim clustering compared to consensus manual clustering on a dataset composed of 160 images of bivariate FCM data had a mean Adjusted Rand Index of 0.90, demonstrating its efficiency in identifying similar patterns. flowSim selectively discarded near duplicate files in datasets constructed with known redundancy, and removed 92.6% of FCM images in a dataset of over 500,000 drawn from public repositories.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Terry Fox Laboratory, BC Cancer Research, Vancouver, British Columbia, Canada.
- Department of Medical Genetics, University of British Columbia, Vancouver, British Columbia, Canada.
ORCID-Profile: Sebastiano Montante
Förderung
- NIBIB NIH HHS
- NIAID NIH HHS
- National Institutes of Health
- Natural Sciences and Engineering Research Council of Canada
Zitieren
APA
Montante, S., Chen, Y., & Brinkman, R. R. (2023). flowSim : Near duplicate detection for flow cytometry data. Cytometry Part A, 103(11), 889-901. https://doi.org/10.1002/cyto.a.24776
Vancouver
Montante S, Chen Y, Brinkman RR. flowSim : Near duplicate detection for flow cytometry data. Cytometry Part A. 2023;103(11):889-901. doi:10.1002/cyto.a.24776
BibTeX
@article{Montante2023,
author = {Montante, Sebastiano and Chen, Yixuan and Brinkman, Ryan R},
title = {flowSim : Near duplicate detection for flow cytometry data},
journal = {Cytometry Part A},
year = {2023},
volume = {103},
number = {11},
pages = {889--901},
doi = {10.1002/cyto.a.24776}
}
EUVIMED