EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Fourier‐transform mid‐infrared spectroscopy for in vitro protein digestibility measurement of pulse crops

Amod Madurapperumage, Nathan Windsor, Nathan Johnson, Pushparajah Thavarajah, Leung Tang, Dil Thavarajah

Crop Science · 2025-01 · 65 (1)

DOI: 10.1002/csc2.21300 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Crop Science, online erschienen am 02.07.2024. Verfasst von Amod Madurapperumage und 5 weiteren Autor:innen. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Agricultural Research Service, National Institute of Food and Agriculture.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The standard method of estimating in vitro protein digestibility, the protein digestibility corrected amino acid score (PDCAAS) assay, does not support the expected workflow of a pulse breeding program. This is mainly due to its low‐throughput design and long processing time (∼16–24 h) per sample. Fourier‐transform mid‐infrared (FT‐MIR) spectroscopy has been developed as a high‐throughput phenotyping tool to estimate protein digestibility in pulses. The mid‐infrared region representing the amide I band (1756.81–1586.27 cm −1 ) was utilized to perform chemometric modeling with partial least squares regression (PLSR) to estimate in vitro protein digestibility in dry pea ( Pisum sativum L.), lentil ( Lens culinaris Medik.), and chickpea ( Cicer arietinum L.) flours. The root mean square error of predictions of the developed PLSR models for dry pea, lentil, and chickpea were 0.00039, 0.00024, and 0.00017, respectively. Phenotyping with the FT‐MIR approach is more rapid than with the PDCAAS assay and estimates protein digestibility from the flour of a single seed in a shorter time (∼1–2 min). The FT‐MIR approach is robust as the spectroscopic data are consistent and chemically fingerprint this nutritional trait. Accordingly, FT‐MIR can resolve the phenotypic bottleneck of pulse breeding related to in vitro protein digestibility measurements by enabling a high‐throughput phenotyping workflow.

Förderung

  • Agricultural Research Service
  • National Institute of Food and Agriculture

Zitieren

APA

Madurapperumage, A., Windsor, N., Johnson, N., Thavarajah, P., Tang, L., & Thavarajah, D. (2025). Fourier‐transform mid‐infrared spectroscopy for in vitro protein digestibility measurement of pulse crops. Crop Science, 65(1). https://doi.org/10.1002/csc2.21300

Vancouver

Madurapperumage A, Windsor N, Johnson N, Thavarajah P, Tang L, Thavarajah D. Fourier‐transform mid‐infrared spectroscopy for in vitro protein digestibility measurement of pulse crops. Crop Science. 2025;65(1). doi:10.1002/csc2.21300

BibTeX
@article{Madurapperumage2025,
  author = {Madurapperumage, Amod and Windsor, Nathan and Johnson, Nathan and Thavarajah, Pushparajah and Tang, Leung and Thavarajah, Dil},
  title = {Fourier‐transform mid‐infrared spectroscopy for in vitro protein digestibility measurement of pulse crops},
  journal = {Crop Science},
  year = {2025},
  volume = {65},
  number = {1},
  doi = {10.1002/csc2.21300}
}
Kostenlos starten →