Fourier‐transform mid‐infrared spectroscopy for in vitro protein digestibility measurement of pulse crops
Crop Science · 2025-01 · 65 (1)
DOI: 10.1002/csc2.21300 ↗Kurz gefasst
Fachartikel in der Zeitschrift Crop Science, online erschienen am 02.07.2024. Verfasst von Amod Madurapperumage und 5 weiteren Autor:innen. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Agricultural Research Service, National Institute of Food and Agriculture.
Abstract (Originalsprache)
The standard method of estimating in vitro protein digestibility, the protein digestibility corrected amino acid score (PDCAAS) assay, does not support the expected workflow of a pulse breeding program. This is mainly due to its low‐throughput design and long processing time (∼16–24 h) per sample. Fourier‐transform mid‐infrared (FT‐MIR) spectroscopy has been developed as a high‐throughput phenotyping tool to estimate protein digestibility in pulses. The mid‐infrared region representing the amide I band (1756.81–1586.27 cm −1 ) was utilized to perform chemometric modeling with partial least squares regression (PLSR) to estimate in vitro protein digestibility in dry pea ( Pisum sativum L.), lentil ( Lens culinaris Medik.), and chickpea ( Cicer arietinum L.) flours. The root mean square error of predictions of the developed PLSR models for dry pea, lentil, and chickpea were 0.00039, 0.00024, and 0.00017, respectively. Phenotyping with the FT‐MIR approach is more rapid than with the PDCAAS assay and estimates protein digestibility from the flour of a single seed in a shorter time (∼1–2 min). The FT‐MIR approach is robust as the spectroscopic data are consistent and chemically fingerprint this nutritional trait. Accordingly, FT‐MIR can resolve the phenotypic bottleneck of pulse breeding related to in vitro protein digestibility measurements by enabling a high‐throughput phenotyping workflow.
Förderung
- Agricultural Research Service
- National Institute of Food and Agriculture
Zitieren
APA
Madurapperumage, A., Windsor, N., Johnson, N., Thavarajah, P., Tang, L., & Thavarajah, D. (2025). Fourier‐transform mid‐infrared spectroscopy for in vitro protein digestibility measurement of pulse crops. Crop Science, 65(1). https://doi.org/10.1002/csc2.21300
Vancouver
Madurapperumage A, Windsor N, Johnson N, Thavarajah P, Tang L, Thavarajah D. Fourier‐transform mid‐infrared spectroscopy for in vitro protein digestibility measurement of pulse crops. Crop Science. 2025;65(1). doi:10.1002/csc2.21300
BibTeX
@article{Madurapperumage2025,
author = {Madurapperumage, Amod and Windsor, Nathan and Johnson, Nathan and Thavarajah, Pushparajah and Tang, Leung and Thavarajah, Dil},
title = {Fourier‐transform mid‐infrared spectroscopy for in vitro protein digestibility measurement of pulse crops},
journal = {Crop Science},
year = {2025},
volume = {65},
number = {1},
doi = {10.1002/csc2.21300}
}
EUVIMED