In vitro comparison of the physical and mechanical properties of an ormocer with an ormocer‐based composite and a nanocomposite restorative material
Clinical and Experimental Dental Research · 2023
DOI: 10.1002/cre2.756 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Clinical and Experimental Dental Research, 2023. Verfasst von Karien Jansen van Rensburg und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Odontology, School of Dentistry, Oral and Dental Hospital, Faculty of Health Sciences, University of Pretoria, Riviera, South Africa. Hauptthemen laut MEDLINE: Dental Restoration, Permanent, Nanocomposites. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 71 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objectives
To compare an ormocer with a first generation ormocer‐based composite and a nanocomposite in terms of surface roughness, surface hardness, and microleakage. Materials and Methods An ormocer (Admira Fusion), a first generation ormocer‐based composite (Admira) and a nanocomposite (Filtek Z350 XT) were prepared strictly in accordance with the manufacturer's instruction and recommendation to provide optimal material properties. Twelve disk samples of each material were evaluated to assess both surface roughness and surface hardness. For surface roughness, all samples were finished, polished, and Ra values measured with a profilometer. For surface hardness, samples were stored in an incubator, polished and a Vickers diamond indenter was used to record values. For microleakage, 36 standardized, Class V cavities were prepared and randomly divided into three groups. Restored teeth were thermally fatigued, immersed in 2% methylene blue solution for 48 h, sectioned, and scored for occlusal and gingival microleakage.
Results
Statistical significance was set at p < .05. The one‐way analysis of variance identified no significant difference in terms of surface roughness between the three material groups ( p > .05). A significantly higher surface hardness was identified for the nanocomposite compared to both the ormocer ( p < .001) and ormocer‐based composite ( p < .001). Fisher's exact test identified no significant difference in terms of occlusal microleakage ( p = .534) and gingival microleakage ( p = .093) between the three material groups.
Conclusions
No significant differences in terms of surface roughness or microleakage were noted. The nanocomposite was significantly harder than the ormocer materials.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Odontology, School of Dentistry, Oral and Dental Hospital, Faculty of Health Sciences, University of Pretoria, Riviera, South Africa.
ORCID-Profile: Karien Jansen van Rensburg, Samantha Arnold
Zitieren
APA
Jansen van Rensburg, K., Kritzinger, D., Arnold, S., & Buchanan, G. D. (2023). In vitro comparison of the physical and mechanical properties of an ormocer with an ormocer‐based composite and a nanocomposite restorative material. Clinical and Experimental Dental Research. https://doi.org/10.1002/cre2.756
Vancouver
Jansen van Rensburg K, Kritzinger D, Arnold S, Buchanan GD. In vitro comparison of the physical and mechanical properties of an ormocer with an ormocer‐based composite and a nanocomposite restorative material. Clinical and Experimental Dental Research. 2023. doi:10.1002/cre2.756