Comparative Analysis of Macro and Zoom Lenses for Dental Shade Selection: An In Vitro Study

Ahmed Ali Jasim iD, Huda Ahmed Abdullah iD, Amer Abbas Mohammed iD, Samah Fadhil Al-Qazzaz iD, Mafaz Mahdi Mohsin iD

Clinical and Experimental Dental Research · 2026-10 · 12 (5)

DOI: 10.1002/cre2.70484 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Clinical and Experimental Dental Research, online erschienen am 11.10.2026. Verfasst von Ahmed Ali Jasim und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Operative Dentistry, Al-Mustansiriya University, Al-Rusafa, Baghdad, Iraq. Hauptthemen laut MEDLINE: Prosthesis Coloring, Dental Prosthesis Design, Lenses. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

This in vitro study evaluated the color accuracy and image sharpness of common macro and zoom lenses on a full‐frame body and tested whether differences among macro‐lens brands are clinically meaningful. Materials and Methods 26 VITA 3D‐Master shade tabs were each photographed three times under standardized, cross‐polarized conditions on a Nikon D610. Three macro lenses (Nikon 105 mm, Sigma 105 mm, and Tamron 90 mm) and four zoom lenses (Nikon 24–70 mm, Nikon 24–120 mm, Sigma 24–70 mm, and Nikon 24–85 mm) were compared. RAW files were converted to CIELAB; reference L * a * b * values were obtained with a 45°/0° spectroradiometer under D65. Color difference (ΔEab, CIE76) was computed for every image. Sharpness was assessed by ISO 12233 slanted‐edge SFR (MTF50) at f/16 and f/22. Linear mixed‐effects models with shade tab as a random effect were fitted; equivalence was tested with two one‐sided tests (TOST) at a prespecified ΔEab margin of 0.6.

Results

All macro lenses produced low, clinically acceptable color errors (mean Δ E ab = 1.2; SD = 0.2) with negligible inter‐brand differences, and all macro–macro comparisons met the 0.6 equivalence margin. Zoom lenses showed significantly higher errors (mean = 2.95–3.35; SD = 0.42–0.50) and failed equivalence. Brand differences among macro lenses were non‐significant ( F = 0.92, p = 0.40), whereas macro‐vs‐zoom differences were highly significant ( F = 792.1, p < 0.0001); 81% of pooled zoom images exceeded the ΔEab acceptability threshold of 2.7, versus none of the macro images. MTF50 confirmed superior macro sharpness, with macro–macro differences within ±5% of the Nyquist frequency.

Conclusions

Dedicated macro lenses are required for accurate shade photography, with general‐purpose zoom lenses producing clinically unacceptable color errors.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Prosthesis ColoringDental Prosthesis DesignLensesHumansColorColorimetryIn Vitro Techniques

Stichwörter der Autor:innen

CIELABcolor difference (ΔEab)cross‐polarizationdental photographymacro lensshade matching

Autor:innen und Institutionen

  • Department of Operative Dentistry, Al-Mustansiriya University, Al-Rusafa, Baghdad, Iraq.
  • Department of Pediatric Orthodontic and Preventive Dentistry, College of Dentistry, Al-Mustansiriya University, Al-Rusafa, Baghdad, Iraq.
  • Department of Pediatric Orthodontic and Preventive Dentistry, College of Dentistry, Al-Bayan University, Baghdad, Iraq.

ORCID-Profile: Ahmed Ali Jasim, Huda Ahmed Abdullah, Amer Abbas Mohammed, Samah Fadhil Al-Qazzaz, Mafaz Mahdi Mohsin

Zitieren

APA

Jasim, A. A., Abdullah, H. A., Mohammed, A. A., Al-Qazzaz, S. F., & Mohsin, M. M. (2026). Comparative Analysis of Macro and Zoom Lenses for Dental Shade Selection: An In Vitro Study. Clinical and Experimental Dental Research, 12(5). https://doi.org/10.1002/cre2.70484

Vancouver

Jasim AA, Abdullah HA, Mohammed AA, Al-Qazzaz SF, Mohsin MM. Comparative Analysis of Macro and Zoom Lenses for Dental Shade Selection: An In Vitro Study. Clinical and Experimental Dental Research. 2026;12(5). doi:10.1002/cre2.70484

BibTeX
@article{Jasim2026,
  author = {Jasim, Ahmed Ali and Abdullah, Huda Ahmed and Mohammed, Amer Abbas and Al-Qazzaz, Samah Fadhil and Mohsin, Mafaz Mahdi},
  title = {Comparative Analysis of Macro and Zoom Lenses for Dental Shade Selection: An In Vitro Study},
  journal = {Clinical and Experimental Dental Research},
  year = {2026},
  volume = {12},
  number = {5},
  doi = {10.1002/cre2.70484}
}
Kostenlos starten →