Detection and Classification of Peri‐Implant Marginal Bone Loss in Cone‐Beam Computed Tomography Using a Deep Learning Approach
Clinical and Experimental Dental Research · 2026-04 · 12 (2)
DOI: 10.1002/cre2.70308 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical and Experimental Dental Research, online erschienen am 17.02.2026. Verfasst von Zahra Madani und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Maxillofacial Radiology, Faculty of Dentistry, Tehran University of Medical Sciences, Tehran, Iran. Hauptthemen laut MEDLINE: Cone-Beam Computed Tomography, Deep Learning, Dental Implants, Alveolar Bone Loss. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objectives
Modern dental implants have high long‐term survival, but peri‐implant marginal bone loss remains a multifactorial cause of implant failure and often is radiographically occult. Cone‐beam computed tomography (CBCT) provides superior 3D assessment but produces large datasets requiring expert interpretation. Deep‐learning object‐detection models like YOLOv8 may automate detection and grading. This study aimed to evaluate a YOLOv8‐based model for automated detection and grading of peri‐implant marginal bone loss on 2D images derived from CBCT. Materials and Methods This retrospective study used 699 2D CBCT sections. Marginal bone loss was graded into four classes (≤ 20%, 21%–40%, 41%–60%, > 61% of implant length). A YOLOv8 detector was trained on 600 × 600‐pixel images (bounding box width 20 px) with two classes (implant, bone loss), split 80/10/10 (train/test/val), 200 epochs, batch size 8 and tuned hyperparameters. Performance was assessed by accuracy, precision, recall, and F1‐score.
Results
The YOLOv8 model achieved strong diagnostic performance on the test set, with overall accuracy, precision, recall, and F1‐score of 0.90. It performed best for healthy sites (precision 0.92, recall 0.99, F1 0.95) and maintained high performance for mild lesions (F1 0.90), while moderate and severe cases showed reduced metrics (F1 0.62 and 0.70, respectively). A three‐class scheme had 0.88 accuracy and excellent reliability (Kappa = 0.954). Detection metric included mAP@0.5 (mean precision at intersection over union threshold of 0.5) of 0.889, a recall of 0.98 at low threshold, and implant‐length detection accuracy of 1.00. Training stabilized after about 15 epochs.
Conclusions
The YOLOv8‐based deep learning model can reliably detect and grade peri‐implant marginal bone loss on CBCT images. Future research should expand datasets, incorporate multimodal information, and validate performance across diverse clinical settings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Maxillofacial Radiology, Faculty of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.
ORCID-Profile: Zahra Madani, Hoorieh Bashizadeh Fakhar
Zitieren
APA
Madani, Z., & Fakhar, H. B. (2026). Detection and Classification of Peri‐Implant Marginal Bone Loss in Cone‐Beam Computed Tomography Using a Deep Learning Approach. Clinical and Experimental Dental Research, 12(2). https://doi.org/10.1002/cre2.70308
Vancouver
Madani Z, Fakhar HB. Detection and Classification of Peri‐Implant Marginal Bone Loss in Cone‐Beam Computed Tomography Using a Deep Learning Approach. Clinical and Experimental Dental Research. 2026;12(2). doi:10.1002/cre2.70308
BibTeX
@article{Madani2026,
author = {Madani, Zahra and Fakhar, Hoorieh Bashizadeh},
title = {Detection and Classification of Peri‐Implant Marginal Bone Loss in Cone‐Beam Computed Tomography Using a Deep Learning Approach},
journal = {Clinical and Experimental Dental Research},
year = {2026},
volume = {12},
number = {2},
doi = {10.1002/cre2.70308}
}
EUVIMED