Complete Digital Workflow for Evaluation of the Three‐Dimensional Monson's Sphere Using Digital Scanning
Clinical and Experimental Dental Research · 2025
DOI: 10.1002/cre2.70063 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical and Experimental Dental Research, 2025. Verfasst von Cheng Wen und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Stomatology, The Third Affiliated Hospital of Shenzhen University, Shenzhen Luohu Hospital Group Luohu People's Hospital, Shenzhen, Gua…. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Workflow. Die Arbeit nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: This work was supported by funding from the Soft Science Research Project of Luohu District (Grant Number: LX202202090)..
Abstract (Originalsprache)
Background
As a combination of curve of Spee and curve of Wilson, the Monson sphere reflects the arrangement of teeth in three‐dimensional (3D) space. For occlusal analysis, the Monson sphere can provide an important reference for prosthetic reconstructions or orthodontic treatments.
Objectives
The purpose of this study was to generate and investigate the 3‐D Monson sphere through a complete digital workflow with intraoral scanning models and custom software. Material and Methods Sixty‐four Chinese adults (32 males and 32 females) with individual normal occlusion were recruited, and their intraoral scanning models were obtained using a digital intraoral scanner. Twenty‐six landmarks on the scanning models were digitized using a reverse engineering software. Monson's sphere was generated and evaluated by fitting a sphere to the cusp tips using a least‐squares method by means of custom software program. Mann–Whitney's U test was performed to test the radius difference of Monson's sphere between males and females. One‐sample t ‐test was used to test the statistical significance (α = 0.05).
Results
Monson's sphere could be generated by means of digital scanning combined with customed software. The mean radius of Monson's sphere was 77.35 ± 13.38 mm, which was lower than the theoretical value proposed by Monson. Furthermore, there were significant differences between males and females in Monson's sphere radius ( p < 0.001).
Conclusions
This study explores a new best‐fit algorithm for generating 3‐D Monson's sphere by complete digital workflow. The radius of Monson's sphere in Chinese adults was lower than the classical value of four‐inch proposed by Monson. There was a significant difference between males and females. Monson's sphere value found in this study could be used as a reference for prosthetic reconstruction and orthodontic treatment and be applied to improve dental treatment results.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Stomatology, The Third Affiliated Hospital of Shenzhen University, Shenzhen Luohu Hospital Group Luohu People's Hospital, Shenzhen, Guangdong, China.
ORCID-Profile: Jin Cheng Wu
Förderung
- This work was supported by funding from the Soft Science Research Project of Luohu District (Grant Number: LX202202090).
Zitieren
APA
Wen, C., Wang, H. H., Muhetaer, H. J., Xie, F., Han, R., & Wu, J. C. (2025). Complete Digital Workflow for Evaluation of the Three‐Dimensional Monson's Sphere Using Digital Scanning. Clinical and Experimental Dental Research. https://doi.org/10.1002/cre2.70063
Vancouver
Wen C, Wang HH, Muhetaer HJ, Xie F, Han R, Wu JC. Complete Digital Workflow for Evaluation of the Three‐Dimensional Monson's Sphere Using Digital Scanning. Clinical and Experimental Dental Research. 2025. doi:10.1002/cre2.70063
BibTeX
@article{Wen2025,
author = {Wen, Cheng and Wang, Huan Huan and Muhetaer, Huo Jia and Xie, Fan and Han, Rui and Wu, Jin Cheng},
title = {Complete Digital Workflow for Evaluation of the Three‐Dimensional Monson's Sphere Using Digital Scanning},
journal = {Clinical and Experimental Dental Research},
year = {2025},
doi = {10.1002/cre2.70063}
}