EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Enhancing Implant Position Accuracy in Guided Implantology: The Role of Drill Play Under Lateral Forces

Vasilios Alevizakos iD, Yannick Stryga, Constantin von See

Clinical and Experimental Dental Research · 2024

DOI: 10.1002/cre2.70056 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical and Experimental Dental Research, 2024. Verfasst von Vasilios Alevizakos und 2 weiteren Autor:innen. Beteiligte Einrichtung: Research Centre for Digital Technologies in Dentistry and CAD/CAM, Department of Dentistry, Faculty of Medicine and Dentistry, Danube Private Univers…. Hauptthemen laut MEDLINE: Surgery, Computer-Assisted, Printing, Three-Dimensional. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 11 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The authors received no specific funding for this work..

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

This study investigates the impact of drill play on the precision of implant positioning under lateral forces in guided implantology. Materials and Methods An in vitro experiment was conducted using artificial bone blocks and the SIC Invent‐guided surgery implant system. Custom drill guides were designed, and 3D‐printed, using three sleeve types: sleeveless, a big sleeve, and a small sleeve. Drillings were performed with varying lateral forces, and deviations in angle, depth, and position were measured.

Results

Sleeveless guides showed the highest variability in deviations, with a maximum deviation of 3.92 mm under extreme lateral forces. Big sleeve guides provided the most consistent precision, with deviations ranging from 0.42 to 1.33 mm. Small sleeve guides showed moderate precision, with deviations from 0.14 to 2.17 mm. Higher lateral forces generally increased deviations across all guide types.

Conclusions

Drill play significantly affects the precision of guided implant drilling, with lateral forces causing deviations from the planned implant position. Big sleeve guides offer better precision under lateral loads compared to sleeveless and small sleeve guides. Strict adherence to the drilling protocol is essential to minimize errors and ensure optimal implant positioning.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Surgery, Computer-AssistedPrinting, Three-DimensionalHumansDental Implantation, EndosseousEquipment DesignDental Implants

Stichwörter der Autor:innen

drill playguided implantologyimplant positioninglateral forcessurgical guide

Substanzen

Dental Implants

Autor:innen und Institutionen

  • Research Centre for Digital Technologies in Dentistry and CAD/CAM, Department of Dentistry, Faculty of Medicine and Dentistry, Danube Private University, Krems an der Donau, Austria.

ORCID-Profile: Vasilios Alevizakos

Förderung

  • The authors received no specific funding for this work.

Zitieren

APA

Alevizakos, V., Stryga, Y., & von See, C. (2024). Enhancing Implant Position Accuracy in Guided Implantology: The Role of Drill Play Under Lateral Forces. Clinical and Experimental Dental Research. https://doi.org/10.1002/cre2.70056

Vancouver

Alevizakos V, Stryga Y, von See C. Enhancing Implant Position Accuracy in Guided Implantology: The Role of Drill Play Under Lateral Forces. Clinical and Experimental Dental Research. 2024. doi:10.1002/cre2.70056

BibTeX
@article{Alevizakos2024,
  author = {Alevizakos, Vasilios and Stryga, Yannick and von See, Constantin},
  title = {Enhancing Implant Position Accuracy in Guided Implantology: The Role of Drill Play Under Lateral Forces},
  journal = {Clinical and Experimental Dental Research},
  year = {2024},
  doi = {10.1002/cre2.70056}
}
Infokarte | EUVIMED