The Accuracy of the CBCT‐Based 3‐Dimensional Replica of the Donor Tooth in Autotransplantation
Clinical and Experimental Dental Research · 2024
DOI: 10.1002/cre2.70032 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical and Experimental Dental Research, 2024. Verfasst von Jessica Juslin und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oral and Maxillofacial Surgery, University of Turku, Turku, Finland. Hauptthemen laut MEDLINE: Cone-Beam Computed Tomography, Imaging, Three-Dimensional, Transplantation, Autologous. Die Arbeit nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The authors received no specific funding for this work..
Abstract (Originalsprache)
Background
This study evaluated the accuracy of the CBCT reconstruction model compared to the natural tooth and the accuracy of the replica tooth compared to the natural tooth.
Objective
The hypothesis was that a replica tooth could be used as a surgical guide in autotransplantation.
Methods
Three teeth were chosen and a CBCT reconstruction model was formed from each tooth. STL‐data was transferred to a milling machine and replica teeth were milled from PEEK. A digitized surface model was prepared from the natural and the replica teeth by a stereophotogrammetry scanner. The surface model from the optical scan of the natural tooth was compared to the CBCT reconstruction model and the surface model of the replica tooth. The models were matched on each other, and surface‐based rigid registration was performed between the surface models. Distances were calculated and visualized by MATLAB.
Results
The CBCT reconstruction model and the natural tooth were compared. The largest euclidean distance was found at the root tip in the premolar (0.93 mm) and at the furcation area in the molar (2.3 mm). When the natural tooth and the replica tooth were compared, the largest euclidean distance was found at the root tip in the premolar (1.5 mm) and at the furcation area in the molar (1.9 mm).
Conclusion
A CBCT scan maintains sufficient image quality for tooth autotransplantation planning. The replica tooth corresponded in size and shape to the natural tooth in terms of clinically expected need of precision.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Oral and Maxillofacial Surgery, University of Turku, Turku, Finland.
- Department of Oral and Maxillofacial Diseases, Turku University Hospital, Turku, Finland.
- Department of Pediatric Dentistry and Orthodontics, University of Turku, Turku, Finland.
- Department of Oral Pathology and Oral Radiology, University of Turku, Turku, Finland.
- South West Finland Imaging Centre, Turku University Hospital, Turku, Finland.
- Department of Biomaterials Science, University of Turku, Turku, Finland.
ORCID-Profile: Jessica Juslin
Förderung
- The authors received no specific funding for this work.
Zitieren
APA
Juslin, J., Teerijoki-Oksa, T., Jääsaari, P., Ekholm, M., Vallittu, P., Lassila, L., & Thorén, H. (2024). The Accuracy of the CBCT‐Based 3‐Dimensional Replica of the Donor Tooth in Autotransplantation. Clinical and Experimental Dental Research. https://doi.org/10.1002/cre2.70032
Vancouver
Juslin J, Teerijoki-Oksa T, Jääsaari P, Ekholm M, Vallittu P, Lassila L, et al. The Accuracy of the CBCT‐Based 3‐Dimensional Replica of the Donor Tooth in Autotransplantation. Clinical and Experimental Dental Research. 2024. doi:10.1002/cre2.70032
BibTeX
@article{Juslin2024,
author = {Juslin, Jessica and Teerijoki-Oksa, Tuija and Jääsaari, Päivi and Ekholm, Marja and Vallittu, Pekka and Lassila, Lippo and Thorén, Hanna},
title = {The Accuracy of the CBCT‐Based 3‐Dimensional Replica of the Donor Tooth in Autotransplantation},
journal = {Clinical and Experimental Dental Research},
year = {2024},
doi = {10.1002/cre2.70032}
}
EUVIMED