Multiparametric Flow Cytometry for Determination of Viability, Caspase 3 and 7 Activity, and Lipid Peroxidation Adduct (4‐Hydroxynonenal) in Equine Spermatozoa
Current Protocols · 2023-09 · 3 (9)
DOI: 10.1002/cpz1.885 ↗Kurz gefasst
Fachartikel in der Zeitschrift Current Protocols, online erschienen am 06.09.2023. Verfasst von Carolina Maria Balão da Silva und 3 weiteren Autor:innen. Beteiligte Einrichtung: Polytechnic Institute of Portalegre, Agrarian School of Elvas, Elvas, Portugal. Hauptthemen laut MEDLINE: Fluorescent Dyes, Spermatozoa. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 42 Literaturangaben.
Abstract (Originalsprache)
Flow cytometry is a powerful tool for the analysis of cell samples formed of multipopulations, such as spermatozoa. In recent years, multiparametric cytometers have evolved, allowing the study of different cellular characteristics, such as protein expression, DNA analysis, or mitochondrial activity. Whether using traditional fluorescent dyes or fluorophore‐conjugated antibodies, each cell or cellular component is individually stained, the sample is analyzed at high velocities, and then is displayed and interpreted in a dot‐plot. We hereby describe the procedure to perform a multiparametric flow cytometry analysis in equine spermatozoa using three sources of excitation and polychromatic flow cytometry for the detection of 4HNE, a lipid peroxidation adduct (by anti‐4HNE antibody), apoptotic markers (by caspases 3 and 7 activity), and live/dead spermatozoa (by ethidium‐homodimer) excluding the debris with Hoechst 33342 staining and gating. This multiparametric analysis allows the simultaneous detection of different spermatic parameters, providing useful information for the characterization of a seminal sample and fertility estimation. © 2023 Wiley Periodicals LLC. Basic Protocol : Determination of viability, caspase 3 and 7 activity, and 4‐hydroxynonenal in equine spermatozoa by flow cytometry
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Polytechnic Institute of Portalegre, Agrarian School of Elvas, Elvas, Portugal.
- VALORIZA, Research Centre for Endogenous Resources Valorization, Polytechnic Institute of Portalegre, Portalegre, Portugal.
- Laboratory of Equine Reproduction and Equine Spermatology, Universidad de Extremadura, Cáceres, Spain.
Zitieren
APA
da Silva, C. M. B., Cano, F. E. M., Gaitskell-Phillips, G., & Vega, F. J. P. (2023). Multiparametric Flow Cytometry for Determination of Viability, Caspase 3 and 7 Activity, and Lipid Peroxidation Adduct (4‐Hydroxynonenal) in Equine Spermatozoa. Current Protocols, 3(9). https://doi.org/10.1002/cpz1.885
Vancouver
da Silva CMB, Cano FEM, Gaitskell-Phillips G, Vega FJP. Multiparametric Flow Cytometry for Determination of Viability, Caspase 3 and 7 Activity, and Lipid Peroxidation Adduct (4‐Hydroxynonenal) in Equine Spermatozoa. Current Protocols. 2023;3(9). doi:10.1002/cpz1.885
BibTeX
@article{daSilva2023,
author = {da Silva, Carolina Maria Balão and Cano, Francisco E Martín and Gaitskell-Phillips, Gemma and Vega, Fernando J Peña},
title = {Multiparametric Flow Cytometry for Determination of Viability, Caspase 3 and 7 Activity, and Lipid Peroxidation Adduct (4‐Hydroxynonenal) in Equine Spermatozoa},
journal = {Current Protocols},
year = {2023},
volume = {3},
number = {9},
doi = {10.1002/cpz1.885}
}
EUVIMED