EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Protocols for Assessing Storage Stability and Solubility of Released N‐Linked Glycans Prior to Mass Spectrometry Analysis

Oluwaseun O Ajayi, Tunde A Aduloju

Current Protocols · 2026-11 · 6 (11)

DOI: 10.1002/cpz1.70509 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Current Protocols, online erschienen am 31.10.2026. Verfasst von Oluwaseun O Ajayi und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Franklin College of Arts and Sciences, University of Georgia, Athens, Georgia, USA. Hauptthemen laut MEDLINE: Polysaccharides, Liquid Chromatography-Mass Spectrometry, Mass Spectrometry. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Georgia, Athens.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Released N‐linked glycans are frequently stored between enzymatic release, cleanup, and LC–MS analysis, yet storage solvent and freeze–thaw handling are often reported incompletely or omitted. This unit provides a procedure for determining, within a given laboratory and for a given glycan preparation, whether a selected storage condition preserves analytical performance prior to LC–ion mobility–mass spectrometry (LC–IM–MS). The workflow compares matched aliquots prepared from a single cleared glycan stock, using extracted ion chromatogram signal intensity, chromatographic peak shape, visible precipitation, and replicate precision as acceptance criteria, assessed both before and after a controlled freeze–thaw cycle. A worked example comparing 0.1% (v/v) formic acid in water with 50:50 acetonitrile:water is presented to demonstrate the workflow. The aqueous condition retained LC–IM–MS signal after one freeze–thaw cycle, while the acetonitrile‐containing condition showed substantial post‐thaw signal loss despite acceptable pre‐freeze performance. This example illustrates the magnitude of effect that storage solvent can produce and is not presented as a general storage recommendation, since susceptibility is both structure dependent and platform dependent. The protocols are intended for laboratories analyzing released N‐linked glycans from glycoproteins or biological samples and can be applied to PGC‐, reversed‐phase‐, or HILIC‐based LC–MS workflows, with solvent adjustment performed immediately before injection rather than during long‐term storage. © 2026 The Author(s). Current Protocols published by Wiley Periodicals LLC. Basic Protocol 1 : Solvent selection and solubility assessment of released N‐linked glycans before LC–IM–MS analysis Basic Protocol 2 : Freeze–thaw stability evaluation and long‐term aqueous storage of released N‐linked glycan stocks Support Protocol : Preparation of single‐use glycan aliquots and pre‐injection quality control

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PolysaccharidesLiquid Chromatography-Mass SpectrometryMass SpectrometrySolubilityFreezingChromatography, LiquidSpecimen Handling

Stichwörter der Autor:innen

LC–IM–MSN‐linked glycansfreeze–thaw stabilityglycomicssample storage

Substanzen

Polysaccharides

Autor:innen und Institutionen

  • Department of Chemistry, Franklin College of Arts and Sciences, University of Georgia, Athens, Georgia, USA.
  • Department of Applied Biochemistry, Nnamdi Azikiwe University, Awka, Nigeria.

Förderung

  • University of Georgia, Athens

Zitieren

APA

Ajayi, O. O., & Aduloju, T. A. (2026). Protocols for Assessing Storage Stability and Solubility of Released N‐Linked Glycans Prior to Mass Spectrometry Analysis. Current Protocols, 6(11). https://doi.org/10.1002/cpz1.70509

Vancouver

Ajayi OO, Aduloju TA. Protocols for Assessing Storage Stability and Solubility of Released N‐Linked Glycans Prior to Mass Spectrometry Analysis. Current Protocols. 2026;6(11). doi:10.1002/cpz1.70509

BibTeX
@article{Ajayi2026,
  author = {Ajayi, Oluwaseun O and Aduloju, Tunde A},
  title = {Protocols for Assessing Storage Stability and Solubility of Released N‐Linked Glycans Prior to Mass Spectrometry Analysis},
  journal = {Current Protocols},
  year = {2026},
  volume = {6},
  number = {11},
  doi = {10.1002/cpz1.70509}
}
Kostenlos starten →