EUVIMEDEUVIMED entdecken
Crossref

Ratiometric Fluorescence Sensing of Human/Bovine Serum Albumin Using In Situ Formed Fe 3+ Complex

Kanishk Bhardwaj iD, Ritambhara Jangir, Bigyan R Jali, Suban K Sahoo iD

ChemPlusChem · 2026-10 · 91 (10)

DOI: 10.1002/cplu.70275 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ChemPlusChem, online erschienen am 22.10.2026. Verfasst von Kanishk Bhardwaj und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Sardar Vallabhbhai National Institute Technology, Surat, Gujarat, India. Hauptthemen laut MEDLINE: Serum Albumin, Bovine, Ferric Compounds, Serum Albumin, Human, Coordination Complexes. Die Arbeit nennt 40 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The quantification of albumin levels in biological samples is a critical biomarker for diagnosing and monitoring various pathological conditions. This study introduced a vitamin B 6 cofactor derived Schiff base (E)‐(4‐(((2‐(1H‐benzo[d]imidazol‐2‐yl)phenyl)imino)methyl)‐5‐hydroxy‐6‐methylpyridin‐3‐yl)methyl dihydrogen phosphate (BMLP) via the condensation of pyridoxal 5′‐phosphate with 2‐(1H‐benzo[d]imidazol‐2‐yl)aniline. Schiff base BMLP formed a complex with Fe 3+ in 2:1 binding ratio and redshifted its fluorescence emission from 417 to 474 nm, accompanied by slight quenching at 417 nm and fluorescence enhancement at 474 nm. The in situ formed BMLP─Fe 3+ complex was employed for the ratiometric fluorescence sensing of albumins, that is, human serum albumin (HSA) and bovine serum albumin (BSA). With the addition of HSA and BSA, the fluorescence emission of BMLP─Fe 3+ complex was quenched at 474 nm and enhanced at 417 nm. The selective ratiometric response from the BMLP─Fe 3+ complex can be employed to detect HSA and BSA down to 3.8 and 3.6 µM, respectively. The developed fluorescence‐based sensing approach was applied for quantifying HSA and BSA in real biological matrices, including milk and urine, with satisfactory recovery rates.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Serum Albumin, BovineFerric CompoundsSerum Albumin, HumanCoordination ComplexesHumansAnimalsCattleSpectrometry, FluorescenceFluorescent Chemosensor CompoundsSchiff BasesFluorescence

Stichwörter der Autor:innen

Fe(III) complexalbuminsfluorescent sensorratiometric sensingvitamin B6 cofactor

Substanzen

Serum Albumin, BovineFerric CompoundsSerum Albumin, HumanFluorescent Chemosensor CompoundsSchiff BasesCoordination Complexes

Autor:innen und Institutionen

  • Department of Chemistry, Sardar Vallabhbhai National Institute Technology, Surat, Gujarat, India.
  • Department of Chemistry, Veer Surendra Sai University of Technology, Sambalpur, Odisha, India.

ORCID-Profile: Kanishk Bhardwaj, Suban K Sahoo

Zitieren

APA

Bhardwaj, K., Jangir, R., Jali, B. R., & Sahoo, S. K. (2026). Ratiometric Fluorescence Sensing of Human/Bovine Serum Albumin Using In Situ Formed Fe 3+ Complex. ChemPlusChem, 91(10). https://doi.org/10.1002/cplu.70275

Vancouver

Bhardwaj K, Jangir R, Jali BR, Sahoo SK. Ratiometric Fluorescence Sensing of Human/Bovine Serum Albumin Using In Situ Formed Fe 3+ Complex. ChemPlusChem. 2026;91(10). doi:10.1002/cplu.70275

BibTeX
@article{Bhardwaj2026,
  author = {Bhardwaj, Kanishk and Jangir, Ritambhara and Jali, Bigyan R and Sahoo, Suban K},
  title = {Ratiometric Fluorescence Sensing of Human/Bovine Serum Albumin Using In Situ Formed Fe 3+ Complex},
  journal = {ChemPlusChem},
  year = {2026},
  volume = {91},
  number = {10},
  doi = {10.1002/cplu.70275}
}
Kostenlos starten →