Electroactive Copper–Cyanurate Coordination Polymer for Thiosulfate Monitoring in Biological Fluids
ChemPlusChem · 2026
DOI: 10.1002/cplu.202500564 ↗Kurz gefasst
Fachartikel in der Zeitschrift ChemPlusChem, 2026. Verfasst von Muhammad Subhan und 5 weiteren Autor:innen. Beteiligte Einrichtung: Sensors and Diagnostics Lab, School of Chemistry, University of the Punjab, Quaid-i-Azam Campus, Lahore, 54590, Pakistan. Hauptthemen laut MEDLINE: Copper, Thiosulfates, Electrochemical Techniques, Polymers. Die Arbeit nennt 63 Literaturangaben.
Abstract (Originalsprache)
The precise and noninvasive detection of thiosulfate, an essential antidote for cyanide poisoning, is critical for both clinical toxicology and environmental monitoring. In this work, the development of an electroactive copper–cyanurate (Cu–CYA) coordination polymer, engineered as a highly sensitive and selective electrochemical sensor for thiosulfate detection in biological fluids, is reported. The sensor material is synthesized via a straightforward coordination‐driven self‐assembly process, yielding a porous framework with abundant active sites, excellent redox properties, and superior electron transfer capability. Comprehensive physicochemical characterization confirms the structural integrity and favorable interfacial kinetics of the Cu–CYA/graphite pencil electrode (GPE) sensor. Cyclic voltammetry and differential pulse voltammetry analyses reveal a robust and linear response to thiosulfate concentrations ranging from 100 to 500 nM, with a remarkable sensitivity of 2.94 µA cm −2 nM −1 and an exceptionally low limit of detection of 0.32 nM. The sensor exhibits high selectivity against potential interferents and maintains 93.3% of its initial response after 30 days, underscoring its long‐term functional reliability. Notably, real sample analysis using human saliva demonstrates a mean recovery of 97.5%, validating the sensor's practical applicability in complex biological matrices. This study establishes Cu–CYA as a powerful electrochemical sensing platform for thiosulfate monitoring, offering new prospects for portable diagnostics in healthcare and environmental safety.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Sensors and Diagnostics Lab, School of Chemistry, University of the Punjab, Quaid-i-Azam Campus, Lahore, 54590, Pakistan.
- Faculty of Science, Department of Physics, Islamic University of Madinah, Madinah, 42351, Saudi Arabia.
ORCID-Profile: Adeel Afzal
Zitieren
APA
Subhan, M., Naeem, M. M., Farhan, M., Atta, S., Shakir, I., & Afzal, A. (2026). Electroactive Copper–Cyanurate Coordination Polymer for Thiosulfate Monitoring in Biological Fluids. ChemPlusChem. https://doi.org/10.1002/cplu.202500564
Vancouver
Subhan M, Naeem MM, Farhan M, Atta S, Shakir I, Afzal A. Electroactive Copper–Cyanurate Coordination Polymer for Thiosulfate Monitoring in Biological Fluids. ChemPlusChem. 2026. doi:10.1002/cplu.202500564
BibTeX
@article{Subhan2026,
author = {Subhan, Muhammad and Naeem, Muhammad Musharraf and Farhan, Muhammad and Atta, Sadia and Shakir, Imran and Afzal, Adeel},
title = {Electroactive Copper–Cyanurate Coordination Polymer for Thiosulfate Monitoring in Biological Fluids},
journal = {ChemPlusChem},
year = {2026},
doi = {10.1002/cplu.202500564}
}
EUVIMED