Fachartikel in der Zeitschrift ChemPlusChem, online erschienen am 17.05.2024. Verfasst von Haiyan Wei und 4 weiteren Autor:innen. Beteiligte Einrichtung: Pharmacy College, Henan University of Chinese Medicine, Zhengzhou, 450046, P. R. China. Hauptthemen laut MEDLINE: Gold, Metal Nanoparticles, Electrochemical Techniques, Tungsten. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 39 Literaturangaben. Gefördert von: Project of Tackling of Key Scientific and Technical Problems in Henan Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Down‐regulator of transcription 1 (DR1) is considered as a biomarker of hashimoto‘s thyroiditis (HT), which is a risk factor for thyroid cancer. Here, a label‐free electrochemical biosensor for DR1 detection was constructed based on polyamidoamine (PAMAM) polymer and the nanocomposite (WO 3 @AuNPs) composed of tungsten trioxide (WO 3 ) and gold nanoparticles (AuNPs). WO 3 @AuNPs was obtained by combining monolayer WO 3 nanosheets, which has high conductivity, and AuNPs. The modification of WO 3 @AuNPs can not only increase the conductivity of the electrode but also provide more active sites for signaling units, thus greatly improve the sensitivity of the sensor. The polymer PAMAM is biocompatible and non‐immunogenic, and its end functional group can bind to the target molecules, providing them with more binding sites and thus improving the sensitivity of the sensor. Under optimal conditions, the label‐free biosensor showed a good linear relationship between the logarithm of DR1 concentration and the impedance in the range of 10 fg ⋅ mL −1 to 100 ng ⋅ mL −1 , with a detection limit as low as 0.3 fg ⋅ mL −1 . Besides, this label‐free electrochemical platform exhibited satisfactory selectivity and anti‐interference capability in human serum samples. Therefore, this method has considerable potential in clinical detection of DR1.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GoldMetal NanoparticlesElectrochemical TechniquesTungstenOxidesBiosensing TechniquesHumansPolyaminesLimit of Detection

Stichwörter der Autor:innen

Dendritic polymer PAMAMDown-regulator of transcription 1Dual signal amplificationHashimoto's thyroiditisWO3@AuNPs

Substanzen

GoldTungstenOxidestungsten oxidePolyaminesPoly(amidoamine)

Autor:innen und Institutionen

  • Pharmacy College, Henan University of Chinese Medicine, Zhengzhou, 450046, P. R. China.
  • Academy of Chinese Medical Sciences, Henan Key Laboratory of TCM Syndrome and Prescription in Signaling, Henan International Joint Laboratory of TCM Syndrome and Prescription in Signaling, Henan University of Chinese Me…

ORCID-Profile: Huaixia Yang

Förderung

  • Project of Tackling of Key Scientific and Technical Problems in Henan Province

Zitieren

APA

Wei, H., Cui, X., Yang, H., Si, F., & Zhang, Y. (2024). Combining WO 3 @AuNPs with Poly(amidoamine) Allows Sensitive Electrochemical Detection of DR1 Based on Dual Signal Amplification. ChemPlusChem, 89(8). https://doi.org/10.1002/cplu.202400119

Vancouver

Wei H, Cui X, Yang H, Si F, Zhang Y. Combining WO 3 @AuNPs with Poly(amidoamine) Allows Sensitive Electrochemical Detection of DR1 Based on Dual Signal Amplification. ChemPlusChem. 2024;89(8). doi:10.1002/cplu.202400119

BibTeX
@article{Wei2024,
  author = {Wei, Haiyan and Cui, Xiaojing and Yang, Huaixia and Si, Fuchun and Zhang, Yaping},
  title = {Combining WO 3 @AuNPs with Poly(amidoamine) Allows Sensitive Electrochemical Detection of DR1 Based on Dual Signal Amplification},
  journal = {ChemPlusChem},
  year = {2024},
  volume = {89},
  number = {8},
  doi = {10.1002/cplu.202400119}
}
Kostenlos starten →