Development and Verification of a Diagnostic Technology for Waste Battery Deterioration Factors
ChemPhysChem · 02.11.2023 · 24 (21)
DOI: 10.1002/cphc.202300438 ↗Kurz gefasst
Fachartikel in der Zeitschrift ChemPhysChem, online erschienen am 15.09.2023. Verfasst von Sunghun Jung und 5 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Smart Vehicle System Engineering, Chosun University, 101, Chosundae 2-gil, Dong-gu, Gwangju, 61452, Republic of Korea. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 36 Literaturangaben. Gefördert von: Research and Development Program of the Korea Institute of Energy Research.
Abstract (Originalsprache)
We defined four major deterioration factors (electrolyte loss (EL), lithium loss (LL), lithium precipitation (LP), and compound deterioration (CD)). Then, we derived eleven key performance indicators (KPIs) for comparative analysis. After that, we fabricated three deteriorated cells for each of three deterioration factors (EL, LL, and LP) and one cell with CD (for verification) with four individual (dis)charging experiment manuals. The two major contributions of this study are the performance of 1) trend analysis to determine a suitable diagnostic metric by inspecting the eleven KPIs and 2) comparison analysis of and to verify the effectiveness of utilizing as a real‐time deterioration diagnostic factor using a concept of model‐in‐the‐loop simulation. The results show that 1) has the most conspicuous trendline tendency among the eleven comparison targets for all four major deterioration factors, and 2) the angle difference between the two trends of and lies within a minimum of 9° and a maximum of 43° (with a sscale on the x‐axis and a scale on the y‐axis for a clear trend line analysis). From this, we can conclude that the trendline‐based real‐time deterioration analysis employing may be practically applicable to a limited extent.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Faculty of Smart Vehicle System Engineering, Chosun University, 101, Chosundae 2-gil, Dong-gu, Gwangju, 61452, Republic of Korea.
- Gwangju Clean Energy Research Center, Korea Institute of Energy Research, 25, Samso-ro 270 beon-gil, Buk-gu, Gwangju, 61003, Republic of Korea.
- Faculty of Battery Science and Engineering, Dongshin University, 67, Dongsindae-gil, Naju-si, Jeollanam-do, 58245, Republic of Korea.
ORCID-Profile: Sunghun Jung, Jung-Je Woo
Förderung
- Research and Development Program of the Korea Institute of Energy Research
Zitieren
APA
Jung, S., Seo, J. K., Jang, I. C., Kim, J., Shim, J. H., & Woo, J. J. (2023). Development and Verification of a Diagnostic Technology for Waste Battery Deterioration Factors. ChemPhysChem, 24(21). https://doi.org/10.1002/cphc.202300438
Vancouver
Jung S, Seo JK, Jang IC, Kim J, Shim JH, Woo JJ. Development and Verification of a Diagnostic Technology for Waste Battery Deterioration Factors. ChemPhysChem. 2023;24(21). doi:10.1002/cphc.202300438
BibTeX
@article{Jung2023,
author = {Jung, Sunghun and Seo, Joon Kyo and Jang, Il-Chan and Kim, Jihun and Shim, Jae-Hyun and Woo, Jung-Je},
title = {Development and Verification of a Diagnostic Technology for Waste Battery Deterioration Factors},
journal = {ChemPhysChem},
year = {2023},
volume = {24},
number = {21},
doi = {10.1002/cphc.202300438}
}
EUVIMED