Effect of Flowable Resin Liner Thickness on Damage at the Tooth–Restoration Interface: A Finite Element Study
International Journal for Numerical Methods in Biomedical Engineering · 2026-11 · 42 (11)
DOI: 10.1002/cnm.70228 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal for Numerical Methods in Biomedical Engineering, online erschienen am 30.10.2026. Verfasst von Youxin Li und 4 weiteren Autor:innen. Beteiligte Einrichtung: Key Lab for Biomechanical Engineering of Sichuan Province, Sichuan University, Chengdu, China. Hauptthemen laut MEDLINE: Finite Element Analysis, Composite Resins, Dental Restoration, Permanent. Die Arbeit nennt 82 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Strategic Cooperation Project between Sichuan University and Yibin Municipal People's Government.
Abstract (Originalsprache)
This study aims to employ a cohesive zone model (CZM) with finite element analysis to investigate the effect of flowable liner thickness on adhesive damage in Class V resin composite restorations. 3D finite element models of Class V restorations on the mandibular first premolar were created, featuring three distinct cavity shapes: box‐shaped, U‐shaped, and V‐shaped. Each cavity geometry was modeled with four liner conditions (0.00, 0.05, 0.10, and 0.15 mm). The adhesive damage between the restoration and the tooth was characterized using CZM. The loading conditions encompassed both polymerization shrinkage and occlusal forces. The analysis focused on the adhesive damage induced by polymerization shrinkage, occlusal forces, and their combined effects, quantified using the maximum value of the stiffness degradation scalar (SDEG) and the percentage of damage area (PDA). After polymerization shrinkage, peak SDEG and PDA decreased as liner thickness increased. During subsequent occlusal loading, increasing liner thickness was associated with a greater peak SDEG increment, higher PDA at the enamel interface, and lower PDA at the dentin interface. After the full loading sequence, overall PDA decreased with increasing liner thickness, while overall peak SDEG varied only slightly. Within the investigated thickness range, increasing flowable liner thickness reduced polymerization‐shrinkage‐induced adhesive damage but increased peak SDEG increments during subsequent occlusal loading. These numerical findings highlight a load‐dependent mechanical trade‐off associated with liner thickness.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Key Lab for Biomechanical Engineering of Sichuan Province, Sichuan University, Chengdu, China.
- Sichuan University Yibin Park, Yibin Institute of Industrial Technology, Yibin, China.
- Basic Mechanics Lab, Sichuan University, Chengdu, China.
- Department of Biomedical Engineering, The University of Melbourne, Melbourne, Victoria, Australia.
ORCID-Profile: Youxin Li, Haidong Teng, Zhan Liu
Förderung
- National Natural Science Foundation of China
- Strategic Cooperation Project between Sichuan University and Yibin Municipal People's Government
Zitieren
APA
Li, Y., Teng, H., Shao, B., Li, A., & Liu, Z. (2026). Effect of Flowable Resin Liner Thickness on Damage at the Tooth–Restoration Interface: A Finite Element Study. International Journal for Numerical Methods in Biomedical Engineering, 42(11). https://doi.org/10.1002/cnm.70228
Vancouver
Li Y, Teng H, Shao B, Li A, Liu Z. Effect of Flowable Resin Liner Thickness on Damage at the Tooth–Restoration Interface: A Finite Element Study. International Journal for Numerical Methods in Biomedical Engineering. 2026;42(11). doi:10.1002/cnm.70228
BibTeX
@article{Li2026,
author = {Li, Youxin and Teng, Haidong and Shao, Bingmei and Li, Annan and Liu, Zhan},
title = {Effect of Flowable Resin Liner Thickness on Damage at the Tooth–Restoration Interface: A Finite Element Study},
journal = {International Journal for Numerical Methods in Biomedical Engineering},
year = {2026},
volume = {42},
number = {11},
doi = {10.1002/cnm.70228}
}
EUVIMED