Tissue‐Level Neck Response in Rotary‐Wing Aircrew With Head‐Supported Mass Assessed With Finite Element Model
International Journal for Numerical Methods in Biomedical Engineering · 2026-05 · 42 (5)
DOI: 10.1002/cnm.70178 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal for Numerical Methods in Biomedical Engineering, online erschienen am 04.05.2026. Verfasst von Prasannaah Hadagali und 3 weiteren Autor:innen. Beteiligte Einrichtung: Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, Ontario, Canada. Hauptthemen laut MEDLINE: Finite Element Analysis, Neck, Head, Models, Biological. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 98 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Canada Research Chairs, Compute Canada, Natural Sciences and Engineering Research Council of Canada DND/NSERC.
Abstract (Originalsprache)
Epidemiological studies have reported a prevalence of neck pain among rotary‐wing aircrew (RWA), attributed in part to head‐supported mass (HSM) including helmet and night vision goggles (NVG). Combined HSM and movement of the head away from the neutral position results in increased muscle activation and increased loads in the neck; however, the effect of HSM has not been quantified at the tissue level. In the present study, the tissue‐level response to HSM was investigated using a detailed human finite element head–neck (HN) model. Non‐neutral HN positions were achieved by activating the neck muscles, and three conditions were simulated for 25° flexion: (1) baseline HN model (HN F ), (2) HN with helmet (HN F–H ), and (3) HN with helmet, NVG and counterweight (HN F–N ). In addition, a combined HN position was investigated with the helmet, NVG and counterweight, comprising 25° flexion, 8° lateral bending, and 23° axial rotation (HN C–N ). Endplate stresses and annulus fibrosus (AF) fiber strains increased by 17% and 4%, respectively, with the added helmet (HN F to HN F–H ). Endplate stresses and AF fiber strains increased by 24% and 12%, respectively, with the inclusion of NVG and counterweight to the helmet (HN F–H to HN F–N ). In HN C–N , endplate stresses and AF fiber strains further increased by 10% and 9%, respectively, relative to HN F–N . The addition of NVG and counterweight to the helmet had a stronger influence than the helmet alone. The results can potentially quantify the high incidence of neck pain in RWA and can be applied to assess the consequences of mass additions and distribution in future systems.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, Ontario, Canada.
- Kinesiology and Health Sciences, University of Waterloo, Waterloo, Ontario, Canada.
ORCID-Profile: Prasannaah Hadagali, Duane S Cronin
Förderung
- Canada Research Chairs
- Compute Canada
- Natural Sciences and Engineering Research Council of Canada DND/NSERC
- Natural Sciences and Engineering Research Council of Canada
Zitieren
APA
Hadagali, P., Fischer, S. L., Callaghan, J. P., & Cronin, D. S. (2026). Tissue‐Level Neck Response in Rotary‐Wing Aircrew With Head‐Supported Mass Assessed With Finite Element Model. International Journal for Numerical Methods in Biomedical Engineering, 42(5). https://doi.org/10.1002/cnm.70178
Vancouver
Hadagali P, Fischer SL, Callaghan JP, Cronin DS. Tissue‐Level Neck Response in Rotary‐Wing Aircrew With Head‐Supported Mass Assessed With Finite Element Model. International Journal for Numerical Methods in Biomedical Engineering. 2026;42(5). doi:10.1002/cnm.70178
BibTeX
@article{Hadagali2026,
author = {Hadagali, Prasannaah and Fischer, Steven L and Callaghan, Jack P and Cronin, Duane S},
title = {Tissue‐Level Neck Response in Rotary‐Wing Aircrew With Head‐Supported Mass Assessed With Finite Element Model},
journal = {International Journal for Numerical Methods in Biomedical Engineering},
year = {2026},
volume = {42},
number = {5},
doi = {10.1002/cnm.70178}
}
EUVIMED