Hierarchical Poromechanical Approach to Investigate the Impact of Mechanical Loading on Human Skin Micro‐Circulation
International Journal for Numerical Methods in Biomedical Engineering · 2025
DOI: 10.1002/cnm.70066 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal for Numerical Methods in Biomedical Engineering, 2025. Verfasst von Thomas Lavigne und 8 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Computational Engineering, Department of Engineering, University of Luxembourg, Esch-sur-Alzette, Luxembourg. Hauptthemen laut MEDLINE: Skin, Models, Biological, Microcirculation, Skin Physiological Phenomena. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 119 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Fonds National de la Recherche Luxembourg.
Abstract (Originalsprache)
Extensive research on human skin anatomy has revealed that the skin functions as a complex multi‐scale and multi‐phase system, containing up to 70% of bounded and free circulating water. The presence of moving fluids significantly influences the mechanical and biological responses of the skin, affecting its time‐dependent behavior and the transport of essential nutrients and oxygen to cells. Poroelastic modeling emerges as a promising approach to investigate biologically relevant phenomena at finer scales while embedding crucial mechanisms at larger scales as it facilitates the integration of multi‐scale and multi‐physics processes. Despite extensive use of poromechanics in other tissues, no hierarchical multi‐compartment porous model that incorporates blood supply has yet been experimentally evaluated to simulate the in vivo mechanical and micro‐circulatory response of human skin. This paper introduces a hierarchical two‐compartment model that accounts for fluid distribution within the interstitium and the micro‐circulation of blood. A general theoretical framework, which includes a biphasic interstitium (comprising interstitial fluid and non‐structural cells), is formulated and studied through a one‐dimensional consolidation test of a 100 μ m column. The inclusion of a biphasic interstitium allows the model to account separately for the motion of cells and interstitial fluid, recognising their differing characteristic times. An extension of the model to include biological exchanges such as oxygen transport is discussed in the appendix. The preliminary evaluation demonstrated that cell viscosity introduces a second characteristic time beyond that of interstitial fluid movement. However, at high cell viscosity values and short time scales, cells exhibit behavior akin to that of solid materials. Based on these observations, a simplified version of the model was used to replicate an experimental campaign carried out on short time scales. Local pressure (up to 31 kPa) was applied to the skin of the dorsal face of the middle finger through a laser Doppler probe PF801 (Perimed Sweden) attached to an apparatus as previously described (Fromy Brain Res 1998). The model demonstrated its qualitative ability to represent both ischaemia and post‐occlusive reactive hyperaemia, aligning with experimental observations. All numerical simulations were performed using the open source software FEniCSx v0.9.0. To promote transparency and reproducibility, the anonymized experimental data and the corresponding finite element codes are publicly available on GitHub.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Computational Engineering, Department of Engineering, University of Luxembourg, Esch-sur-Alzette, Luxembourg.
- Institut de Biomécanique Humaine Georges Charpak, Arts et Métiers Institute of Technology, Paris, France.
- CNRS, Bordeaux INP, I2M, UMR 5295, I2M Bordeaux, Arts et Metiers Institute of Technology, University of Bordeaux, Talence, France.
- CNRS UMR 5305, Tissue Biology and Therapeutic Engineering Laboratory (LBTI), Lyon, France.
- Claude Bernard University Lyon, Villeurbanne, France.
- Institut Universitaire de France (IUF), France.
ORCID-Profile: Bérengère Fromy, Pierre-Yves Rohan
Förderung
- Fonds National de la Recherche Luxembourg
Zitieren
APA
Lavigne, T., Urcun, S., Fromy, B., Josset-Lamaugarny, A., Lagache, A., Suarez-Afanador, C. A., Bordas, S. P. A., Rohan, P. Y., & Sciumè, G. (2025). Hierarchical Poromechanical Approach to Investigate the Impact of Mechanical Loading on Human Skin Micro‐Circulation. International Journal for Numerical Methods in Biomedical Engineering. https://doi.org/10.1002/cnm.70066
Vancouver
Lavigne T, Urcun S, Fromy B, Josset-Lamaugarny A, Lagache A, Suarez-Afanador CA, et al. Hierarchical Poromechanical Approach to Investigate the Impact of Mechanical Loading on Human Skin Micro‐Circulation. International Journal for Numerical Methods in Biomedical Engineering. 2025. doi:10.1002/cnm.70066
BibTeX
@article{Lavigne2025,
author = {Lavigne, Thomas and Urcun, Stéphane and Fromy, Bérengère and Josset-Lamaugarny, Audrey and Lagache, Alexandre and Suarez-Afanador, Camilo A and Bordas, Stéphane P A and Rohan, Pierre-Yves and Sciumè, Giuseppe},
title = {Hierarchical Poromechanical Approach to Investigate the Impact of Mechanical Loading on Human Skin Micro‐Circulation},
journal = {International Journal for Numerical Methods in Biomedical Engineering},
year = {2025},
doi = {10.1002/cnm.70066}
}
EUVIMED