Modeling Hemodynamic Effects of the Closure Procedure of Carotid Artery Endarterectomy
International Journal for Numerical Methods in Biomedical Engineering · 2025
DOI: 10.1002/cnm.70048 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal for Numerical Methods in Biomedical Engineering, 2025. Verfasst von Laurel Morgan Miller Marsh und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Bioengineering, George Mason University, Fairfax, Virginia, USA. Hauptthemen laut MEDLINE: Endarterectomy, Carotid, Hemodynamics, Models, Cardiovascular, Carotid Arteries. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Travis C. Valentine Memorial.
Abstract (Originalsprache)
Currently, it is unclear why some patients experience restenosis after carotid endarterectomy (CEA) and whether the closing procedure is linked to greater rates of restenosis. Here, the morphology and hemodynamics are compared for the carotid bulb of two patients post‐CEA. One carotid bulb was closed with a patch which later suffered a restenosis, while the other patient's bulb was treated using primary closure and did not. Contrast‐enhanced magnetic resonance angiography (CE‐MRA) was segmented to provide the domain for computational fluid dynamics (CFD). Flowrate waveforms measured with phase‐contrast MR were provided for the common carotid artery (CCA) and internal carotid artery (ICA), while only the mean flow rate was provided for the external carotid artery (ECA), requiring the ECA waveform to be calculated. A Womersley profile was applied to the CCA inlet and ECA outlet, with a traction‐free boundary condition applied to the ICA outlet. The patch patient who restenosed exhibited a nonphysiological hemodynamic environment that differed from the flow environment observed in the healthy, contralateral bulb. In contrast, the hemodynamics of the primary closure patient who underwent a successful CEA showed more favorable levels and trends of WSS as well as healthy mixing from vortices that were both present in the healthy, contralateral bulb. Changing model parameters such as flow rate, wall compliance, and flow waveforms did not alter these conclusions. Therefore, the geometry of the carotid bulb, as opposed to flow characteristics, seems responsible for the observed differences between these two cases in hemodynamic environments and subsequent outcomes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Bioengineering, George Mason University, Fairfax, Virginia, USA.
- Department of Neurosurgery, University of Illinois Chicago, Chicago, Illinois, USA.
ORCID-Profile: Laurel Morgan Miller Marsh, Rainald Löhner, Juan Raul Cebral
Förderung
- Travis C. Valentine Memorial
Zitieren
APA
Marsh, L. M. M., Löhner, R., Abou-Mrad, T., McGuire, L. S., Charbel, F. T., & Cebral, J. R. (2025). Modeling Hemodynamic Effects of the Closure Procedure of Carotid Artery Endarterectomy. International Journal for Numerical Methods in Biomedical Engineering. https://doi.org/10.1002/cnm.70048
Vancouver
Marsh LMM, Löhner R, Abou-Mrad T, McGuire LS, Charbel FT, Cebral JR. Modeling Hemodynamic Effects of the Closure Procedure of Carotid Artery Endarterectomy. International Journal for Numerical Methods in Biomedical Engineering. 2025. doi:10.1002/cnm.70048
BibTeX
@article{Marsh2025,
author = {Marsh, Laurel Morgan Miller and Löhner, Rainald and Abou-Mrad, Tatiana and McGuire, Laura Stone and Charbel, Fady T and Cebral, Juan Raul},
title = {Modeling Hemodynamic Effects of the Closure Procedure of Carotid Artery Endarterectomy},
journal = {International Journal for Numerical Methods in Biomedical Engineering},
year = {2025},
doi = {10.1002/cnm.70048}
}
EUVIMED