EUVIMEDEUVIMED entdecken
Crossref

A Multi‐Scale Computational Model of the Hepatic Circulation Applied to Predict the Portal Pressure After Transjugular Intrahepatic Portosystemic Shunt ( TIPS )

Tianqi Wang iD, Yi Xiang iD, Jitao Wang, Jiaqi Gu, Ling Yang, Deqiang Ma, He Zhu, Tianyu Liu, Chunlong Li, Qi Zhang, Jiahao Han, Deping Ding und 4 weitere

International Journal for Numerical Methods in Biomedical Engineering · 2025

DOI: 10.1002/cnm.3908 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal for Numerical Methods in Biomedical Engineering, 2025. Verfasst von Tianqi Wang und 15 weiteren Autor:innen. Beteiligte Einrichtung: School of Gongli Hospital Medical Technology, University of Shanghai for Science and Technology, Shanghai, China. Hauptthemen laut MEDLINE: Portasystemic Shunt, Transjugular Intrahepatic, Portal Pressure, Liver Circulation, Computer Simulation. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 50 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Noncommunicable Chronic Diseases-National Science and Technology Major Project, The Key Research and Development Program of Jiangsu Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Transjugular intrahepatic portosystemic shunt (TIPS) is a widely used surgery for portal hypertension. In clinical practice, the diameter of the stent forming a shunt is usually selected empirically, which will influence the postoperative portal pressure. Clinical studies found that inappropriate portal pressure after TIPS is responsible for poor prognosis; however, there is no scheme to predict postoperative portal pressure. Therefore, this study aims to develop a computational model applied to predict the portal pressure after TIPS ahead of the surgery. For this purpose, a patient‐specific 0‐3‐D multi‐scale computational model of the hepatic circulation was developed based on preoperative clinical data. The model was validated using the prospectively collected clinical data of 18 patients. Besides, the model of a representative patient was employed in the numerical experiment to further investigate the influences of multiple pathophysiological and surgical factors. Results showed that the difference between the simulated and in vivo measured portal pressures after TIPS was −1.37 ± 3.51 mmHg, and the simulated results were significantly correlated with the in vivo measured results ( r = 0.93, p < 0.0001). Numerical experiment revealed that the estimated model parameters and the severity of possible inherent portosystemic collaterals slightly influenced the simulated results, while the shunt diameter considerably influenced the results. In particular, the existence of catheter for pressure measurement would markedly influence postoperative portal pressure. These findings demonstrated that this computational model is a promising tool for predicting postoperative portal pressure, which would guide the selection of stent diameter and promote individualization and precision of TIPS.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Portasystemic Shunt, Transjugular IntrahepaticPortal PressureLiver CirculationComputer SimulationHumansMiddle AgedFemaleMaleHypertension, PortalAdultAged

Stichwörter der Autor:innen

computational modelhemodynamicsportal hypertensionportal pressuretransjugular intrahepatic portosystemic shunt

Autor:innen und Institutionen

  • School of Gongli Hospital Medical Technology, University of Shanghai for Science and Technology, Shanghai, China.
  • School of Mechanical Engineering, University of Shanghai for Science and Technology, Shanghai, China.
  • Liver Disease Center of Integrated Traditional Chinese and Western Medicine, Department of Radiology, Zhongda Hospital, Medical School, Southeast University, Nurturing Center of Jiangsu Province for State Laboratory of…
  • Basic Medicine Research and Innovation Center of Ministry of Education, Zhongda Hospital, Southeast University; State Key Laboratory of Digital Medical Engineering, Nanjing, China.
  • Xingtai Key Laboratory of Precision Medicine for Liver Cirrhosis and Portal Hypertension, Xingtai People's Hospital, Hebei Medical University, Xingtai, China.
  • School of Clinical Medicine, Tsinghua University, Beijing, China.

ORCID-Profile: Tianqi Wang, Yi Xiang, Xiaolong Qi

Förderung

  • National Natural Science Foundation of China
  • Noncommunicable Chronic Diseases-National Science and Technology Major Project
  • The Key Research and Development Program of Jiangsu Province
  • Fundamental Research Fund of Southeast University
  • Changjiang Scholars Talent Cultivation Project of Zhongda Hospital of Southeast University
  • Research Personnel Cultivation Programme of Zhongda Hospital Southeast University
  • China Postdoctoral Science Foundation
  • Natural Science Foundation of Jiangsu Province

Zitieren

APA

Wang, T., Xiang, Y., Wang, J., Gu, J., Yang, L., Ma, D., Zhu, H., Liu, T., Li, C., Zhang, Q., Han, J., Ding, D., Wang, W., Li, Q., Wan, H., & Qi, X. (2025). A Multi‐Scale Computational Model of the Hepatic Circulation Applied to Predict the Portal Pressure After Transjugular Intrahepatic Portosystemic Shunt ( TIPS ). International Journal for Numerical Methods in Biomedical Engineering. https://doi.org/10.1002/cnm.3908

Vancouver

Wang T, Xiang Y, Wang J, Gu J, Yang L, Ma D, et al. A Multi‐Scale Computational Model of the Hepatic Circulation Applied to Predict the Portal Pressure After Transjugular Intrahepatic Portosystemic Shunt ( TIPS ). International Journal for Numerical Methods in Biomedical Engineering. 2025. doi:10.1002/cnm.3908

BibTeX
@article{Wang2025,
  author = {Wang, Tianqi and Xiang, Yi and Wang, Jitao and Gu, Jiaqi and Yang, Ling and Ma, Deqiang and Zhu, He and Liu, Tianyu and Li, Chunlong and Zhang, Qi and Han, Jiahao and Ding, Deping and Wang, Wei and Li, Qianlong and Wan, Haoguang and Qi, Xiaolong},
  title = {A Multi‐Scale Computational Model of the Hepatic Circulation Applied to Predict the Portal Pressure After Transjugular Intrahepatic Portosystemic Shunt ( TIPS )},
  journal = {International Journal for Numerical Methods in Biomedical Engineering},
  year = {2025},
  doi = {10.1002/cnm.3908}
}
Kostenlos starten →