A quarter of a century biomechanical rupture risk assessment of abdominal aortic aneurysms. Achievements, clinical relevance, and ongoing developments
International Journal for Numerical Methods in Biomedical Engineering · 2023-04 · 39 (4)
DOI: 10.1002/cnm.3587 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal for Numerical Methods in Biomedical Engineering, online erschienen am 28.03.2022. Verfasst von T Christian Gasser und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Engineering Mechanics, KTH Royal Institute of Technology, Stockholm, Sweden. Hauptthemen laut MEDLINE: Aortic Rupture, Aortic Aneurysm, Abdominal. Die Arbeit wurde bisher 31-mal zitiert (Crossref) und nennt 174 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Abdominal aortic aneurysm (AAA) disease, the local enlargement of the infrarenal aorta, is a serious condition that causes many deaths, especially in men exceeding 65 years of age. Over the past quarter of a century, computational biomechanical models have been developed towards the assessment of AAA risk of rupture, technology that is now on the verge of being integrated within the clinical decision‐making process. The modeling of AAA requires a holistic understanding of the clinical problem, in order to set appropriate modeling assumptions and to draw sound conclusions from the simulation results. In this article we summarize and critically discuss the proposed modeling approaches and report the outcome of clinical validation studies for a number of biomechanics‐based rupture risk indices. Whilst most of the aspects concerning computational mechanics have already been settled, it is the exploration of the failure properties of the AAA wall and the acquisition of robust input data for simulations that has the greatest potential for the further improvement of this technology.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Engineering Mechanics, KTH Royal Institute of Technology, Stockholm, Sweden.
- Faculty of Health Sciences, University of Southern Denmark, Odense, Denmark.
- Department of Applied Mechanics, VSB-Technical University of Ostrava, Ostrava-Poruba, Czech Republic.
- Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden.
- Department of Vascular Surgery, Karolinska University Hospital, Stockholm, Sweden.
Zitieren
APA
Gasser, T. C., Miller, C., Polzer, S., & Roy, J. (2023). A quarter of a century biomechanical rupture risk assessment of abdominal aortic aneurysms. Achievements, clinical relevance, and ongoing developments. International Journal for Numerical Methods in Biomedical Engineering, 39(4). https://doi.org/10.1002/cnm.3587
Vancouver
Gasser TC, Miller C, Polzer S, Roy J. A quarter of a century biomechanical rupture risk assessment of abdominal aortic aneurysms. Achievements, clinical relevance, and ongoing developments. International Journal for Numerical Methods in Biomedical Engineering. 2023;39(4). doi:10.1002/cnm.3587
BibTeX
@article{Gasser2023,
author = {Gasser, T Christian and Miller, Christopher and Polzer, Stanislav and Roy, Joy},
title = {A quarter of a century biomechanical rupture risk assessment of abdominal aortic aneurysms. Achievements, clinical relevance, and ongoing developments},
journal = {International Journal for Numerical Methods in Biomedical Engineering},
year = {2023},
volume = {39},
number = {4},
doi = {10.1002/cnm.3587}
}