EUVIMEDEUVIMED entdecken
Crossref

Absorbance spectral slopes for monitoring tropical peat water dissolved organic matter fractions during microbubble pre‐ozonation

Suprihanto Notodarmojo, Muammar Qadafi, Yuniati Zevi

CLEAN – Soil, Air, Water · 2023-08 · 51 (8)

DOI: 10.1002/clen.202300122 ↗

Kurz gefasst

Fachartikel in der Zeitschrift CLEAN – Soil, Air, Water, online erschienen am 22.05.2023. Verfasst von Suprihanto Notodarmojo und 2 weiteren Autor:innen. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 69 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The dissolved organic matter (DOM) protonated fractions of various hydrophobicities were correlated with the tropical peat waters' UV–Vis spectral slopes. This study was conducted to determine how microbubble pre‐ozonation affects UV–Vis spectral slopes in tropical peat water treatment processes This study was conducted to determine how microbubble pre‐ozonation affects UV–Vis spectral slopes in tropical peat water treatment processes. Microbubble pre‐ozonation was carried out at pH 7 followed by alum coagulation and activated carbon (AC) adsorption. The results showed that the log‐transformed UV–Vis absorption of processed peat water had four spectral slopes in the range of 220 to 420 nm. The degradation of the transphilic (TPH) DOM fraction had a strong negative correlation with the S 220‐240 and S 241‐272 values ( R 2 > 0.85). Similarly, the hydrophilic‐charged (HPIC) and hydrophilic‐neutral (HPIN) fractions had a strong negative correlation with the S 220‐240 and S 241‐272 values ( R 2 > 0.84 and R 2 > 0.70). Meanwhile, the S 273‐350 S >350 values had a low and negligible correlation with all analyzed DOM fractions ( R 2 < 0.30). The lower wavelength spectral slopes ratio (S 220‐240 /S 241‐272 ) was moderately correlated with the DOM fraction, while the correlation with higher wavelength values was negligible. Based on these findings, the UV–Vis spectral slopes ratio at lower wavelengths appears to be useful information for developing a surrogate parameter of DOM fractions in peat water treatment processes.

Zitieren

APA

Notodarmojo, S., Qadafi, M., & Zevi, Y. (2023). Absorbance spectral slopes for monitoring tropical peat water dissolved organic matter fractions during microbubble pre‐ozonation. CLEAN – Soil, Air, Water, 51(8). https://doi.org/10.1002/clen.202300122

Vancouver

Notodarmojo S, Qadafi M, Zevi Y. Absorbance spectral slopes for monitoring tropical peat water dissolved organic matter fractions during microbubble pre‐ozonation. CLEAN – Soil, Air, Water. 2023;51(8). doi:10.1002/clen.202300122

BibTeX
@article{Notodarmojo2023,
  author = {Notodarmojo, Suprihanto and Qadafi, Muammar and Zevi, Yuniati},
  title = {Absorbance spectral slopes for monitoring tropical peat water dissolved organic matter fractions during microbubble pre‐ozonation},
  journal = {CLEAN – Soil, Air, Water},
  year = {2023},
  volume = {51},
  number = {8},
  doi = {10.1002/clen.202300122}
}
Kostenlos starten →