Updated Meta‐Analysis of Left Bundle Branch Area Pacing Versus Right Ventricular Pacing in Conduction System Disorders: Insights From New Evidence
Clinical Cardiology · 2026
DOI: 10.1002/clc.70278 ↗Kurz gefasst
Metaanalyse in der Zeitschrift Clinical Cardiology, 2026. Verfasst von Rehan Ishaque und 9 weiteren Autor:innen. Beteiligte Einrichtung: Internal Medicine, Liaquat University of Medical Health & Sciences, Jamshoro, Pakistan. Hauptthemen laut MEDLINE: Cardiac Pacing, Artificial, Heart Ventricles, Ventricular Function, Left, Bundle of His. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Introduction
Right ventricular pacing (RVP) has long been the standard therapy for bradyarrhythmias but may induce ventricular dyssynchrony and adverse cardiac remodeling. Physiologic pacing strategies that preserve the native conduction system, particularly left bundle branch area pacing (LBBAP), have emerged as promising alternatives. This study aimed to evaluate the comparative efficacy and safety of LBBAP versus RVP through an updated meta‐analysis.
Methods
Following PRISMA guidelines, we systematically searched PubMed, Cochrane CENTRAL, and ClinicalTrials.gov for relevant studies published through June 2025. Studies comparing LBBAP and RVP in patients undergoing pacemaker implantation were included. Pooled estimates were calculated using random‐effects models.
Results
A total of 40 studies comprising 8290 patients were included. LBBAP was associated with significantly shorter QRS duration compared with RVP (30 studies, n = 5510; MD −35.56 ms, 95% CI −41.88 to −29.24; p < 0.0001). Structural remodeling also favored LBBAP, with greater improvement in left ventricular ejection fraction (16 studies, n = 1693; MD +3.77%, 95% CI 2.43–5.12; p < 0.0001) and greater reduction in left ventricular end‐diastolic diameter (13 studies, n = 1666; MD −2.33 mm, 95% CI −3.59 to −1.07; p < 0.0001). Clinically, LBBAP was associated with lower heart failure hospitalization (RR 0.38, 95% CI 0.29–0.52; p < 0.0001) and reduced all‐cause mortality (RR 0.55, 95% CI 0.41–0.72; p < 0.0001), along with greater reduction in NT‐proBNP levels.
Conclusion
LBBAP provides superior electrical synchrony, improved cardiac remodeling, and favorable clinical outcomes compared with RVP, while maintaining a comparable procedural safety profile.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Internal Medicine, Liaquat University of Medical Health & Sciences, Jamshoro, Pakistan.
- Michigan State University, Lansing, Michigan, USA.
- Shaheed Mohtarma Benazir Bhutto Medical College, Karachi, Pakistan.
- Mayo Clinic Rochester, Rochester, Minnesota, USA.
- Ghulam Muhammad Mahar Medical College, Sukkur, Pakistan.
- FFCA South High School, Calgary, Alberta, Canada.
ORCID-Profile: Rehan Ishaque
Zitieren
APA
Ishaque, R., Abela, G. S., Ishaque, G., Akram, A., Reya, F. N. U., Memon, F. T., Danish, H., Ikram, A., Baloch, Z. Q., & Rayamajhi, S. (2026). Updated Meta‐Analysis of Left Bundle Branch Area Pacing Versus Right Ventricular Pacing in Conduction System Disorders: Insights From New Evidence. Clinical Cardiology. https://doi.org/10.1002/clc.70278
Vancouver
Ishaque R, Abela GS, Ishaque G, Akram A, Reya FNU, Memon FT, et al. Updated Meta‐Analysis of Left Bundle Branch Area Pacing Versus Right Ventricular Pacing in Conduction System Disorders: Insights From New Evidence. Clinical Cardiology. 2026. doi:10.1002/clc.70278
BibTeX
@article{Ishaque2026,
author = {Ishaque, Rehan and Abela, George S and Ishaque, Ghazal and Akram, Amina and Reya, F N U and Memon, Furqan Tarique and Danish, Hamza and Ikram, Amna and Baloch, Zulfiqar Qutrio and Rayamajhi, Supratik},
title = {Updated Meta‐Analysis of Left Bundle Branch Area Pacing Versus Right Ventricular Pacing in Conduction System Disorders: Insights From New Evidence},
journal = {Clinical Cardiology},
year = {2026},
doi = {10.1002/clc.70278}
}
EUVIMED