Assessment of Point of Care Lung Ultrasound in the Ambulatory Heart Failure Setting
Clinical Cardiology · 2026-02 · 49 (2)
DOI: 10.1002/clc.70244 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Cardiology, online erschienen am 11.02.2026. Verfasst von David Golombeck und 7 weiteren Autor:innen. Beteiligte Einrichtung: Cardiovascular Institute, Northwell, New Hyde Park, New York, USA. Hauptthemen laut MEDLINE: Heart Failure, Lung, Point-of-Care Systems, Ambulatory Care. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 12 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Butterfly Inc, Guilford, CT.
Themen: Herzinsuffizienz
Abstract (Originalsprache)
Background
Limited studies have evaluated lung ultrasound (LUS) in ambulatory heart failure (HF). A six‐zone LUS assesses B‐lines, a marker of congestion. The Butterfly IQ+ probe features an automated B‐line counter (ABLC), eliminating manual counting. We evaluated LUS quality by novice HF providers after training, compared expert manual counts to ABLC, and explored associations between LUS and clinical HF metrics.
Methods
Three novice providers underwent 2 h of didactics and 30 proctored exams. Image quality was independently reviewed by two LUS experts. B‐lines were counted manually by experts and ABLC. We assessed associations between LUS and four clinical metrics: provider‐assessed volume status, > 30% NT‐proBNP increase, > 5 lb weight gain, and PAD above goal (CardioMEMS).
Results
Seventy‐five subjects were enrolled. Overall, LUS quality was excellent, with 88% good quality. Surprisingly, agreement between expert B‐line counts was moderate (Gwet's AC1: 0.49, 95% CI: 0.27 to 0.71) while the accuracy of experts as compared to ABLC was modest (Expert 1 = 61.2%, Expert 2 = 40.3%). Experts correctly identified 93% of positive studies but only 19% of negative studies versus ABLC. Provider volume assessments substantially agreed with LUS (Gwet's AC1: 0.76, 95% CI: 0.61 to 0.91), but providers identified only half of positive LUS cases, suggesting utility in detecting mild volume overload. Only volume overload correlated with positive LUS. Only 25% of subjects had a CardioMEMS.
Conclusion
Novice providers can perform high‐quality LUS after brief training. ABLC reduces B‐line counting variability. LUS detects mild pulmonary congestion undetectable by clinical exam, potentially preventing worsening in HF patients.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Cardiovascular Institute, Northwell, New Hyde Park, New York, USA.
- Biostatistics Unit, Office of Academic Affairs, Northwell, New Hyde Park, New York, USA.
ORCID-Profile: Radiah Khandokar
Förderung
- Butterfly Inc, Guilford, CT
Zitieren
APA
Golombeck, D., Khandokar, R., Fishbein, J., Provenzale, A., Lin, M., McGee, M., Rossi, D., & Maybaum, S. (2026). Assessment of Point of Care Lung Ultrasound in the Ambulatory Heart Failure Setting. Clinical Cardiology, 49(2). https://doi.org/10.1002/clc.70244
Vancouver
Golombeck D, Khandokar R, Fishbein J, Provenzale A, Lin M, McGee M, et al. Assessment of Point of Care Lung Ultrasound in the Ambulatory Heart Failure Setting. Clinical Cardiology. 2026;49(2). doi:10.1002/clc.70244
BibTeX
@article{Golombeck2026,
author = {Golombeck, David and Khandokar, Radiah and Fishbein, Joanna and Provenzale, Allison and Lin, Melodie and McGee, Marsha and Rossi, Dora and Maybaum, Simon},
title = {Assessment of Point of Care Lung Ultrasound in the Ambulatory Heart Failure Setting},
journal = {Clinical Cardiology},
year = {2026},
volume = {49},
number = {2},
doi = {10.1002/clc.70244}
}
EUVIMED