The diagnostic efficiency of artificial intelligence based 2 hours Holter monitoring in premature ventricular and supraventricular contractions detection
Clinical Cardiology · 2024
DOI: 10.1002/clc.24266 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Cardiology, 2024. Verfasst von Qiong Huang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu, China. Hauptthemen laut MEDLINE: Electrocardiography, Ambulatory, Ventricular Premature Complexes. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
Background
Electrocardiography (ECG) and 24 hours Holter monitoring (24 h‐Holter) provided valuable information for premature ventricular and supraventricular contractions (PVC and PSVC). Currently, artificial intelligence (AI) based 2 hours single‐lead Holter (2 h‐Holter) monitoring may provide an improved strategy for PSVC/PVC diagnosis. Hypothesis AI combined with single‐lead Holter monitoring improves PSVC/PVC detection.
Methods
In total, 170 patients were enrolled between August 2022 and 2023. All patients wore both devices simultaneously; then, we compared diagnostic efficiency, including the sensitivity/specificity/positive predictive‐value (PPV) and negative predictive‐value (NPV) in detecting PSVC/PVC by 24 h‐Holter and 2 h‐Holter.
Results
The PPV and NPV in patients underwent 2 h‐Holter were 76.00%/87.50% and 96.35%/98.55, respectively, and the sensitivity and specificity were 79.17%/91.30%, and 95.65%/97.84% in PSVC/PVC detection compared with 24 h‐Holter. The areas under the ROC curves (AUCs) for PSVC and PVC were 0.885 and 0.741, respectively ( p < .0001).
Conclusions
The potential advantages of the 2 h‐Holter were shortened wearing period, improved convenience, and excellent consistency of diagnosis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu, China.
- Department of Cardiac Surgery, The Second Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu, China.
- Department of General Practice, The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu, China.
- Department of Geriatrics, The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu, China.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Huang, Q., Fan, Y., Wang, J., Xu, Z., Yang, L., Wang, J., Zhan, Y., Kong, X., & Zhou, N. (2024). The diagnostic efficiency of artificial intelligence based 2 hours Holter monitoring in premature ventricular and supraventricular contractions detection. Clinical Cardiology. https://doi.org/10.1002/clc.24266
Vancouver
Huang Q, Fan Y, Wang J, Xu Z, Yang L, Wang J, et al. The diagnostic efficiency of artificial intelligence based 2 hours Holter monitoring in premature ventricular and supraventricular contractions detection. Clinical Cardiology. 2024. doi:10.1002/clc.24266
BibTeX
@article{Huang2024,
author = {Huang, Qiong and Fan, Yuansheng and Wang, Jialin and Xu, Zhiyang and Yang, Linfeng and Wang, Junhong and Zhan, Yiyang and Kong, Xiangqing and Zhou, Ningtian},
title = {The diagnostic efficiency of artificial intelligence based 2 hours Holter monitoring in premature ventricular and supraventricular contractions detection},
journal = {Clinical Cardiology},
year = {2024},
doi = {10.1002/clc.24266}
}
EUVIMED