A randomized comparison of retrograde left‐sided versus anterograde right‐sided ablation of the atrioventricular junction
Clinical Cardiology · 2023
DOI: 10.1002/clc.24038 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Clinical Cardiology, 2023. Verfasst von Rajdip Dulai und 6 weiteren Autor:innen. Beteiligte Einrichtung: Cardiology Research Department, Eastbourne District General Hospital, East Sussex Hospitals NHS Trust, Saint Leonards-on-Sea, East Sussex, UK. Hauptthemen laut MEDLINE: Atrial Fibrillation, Catheter Ablation. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Catheter ablation of the atrioventricular node (AVN) is an effective treatment for patients with symptomatic atrial fibrillation. This study compares the success rate, procedure time, radiation time, and complication rates of retrograde left‐sided (LSA) and anterograde right‐sided (RSA) AVN ablation in a randomised controlled trial.
Methods
Thirty‐one patients undergoing AVN ablation were randomized to either LSA (15 patients) or RSA (16 patients). Crossover occurred after six unsuccessful radiofrequency (RF) applications.
Results
The LSA cohort had a mean age of 77.00 ± 5.17 and the RSA cohort was 79.44 ± 6.08 ( p = .0240). There were five crossovers from LSA to RSA and there was one crossover from RSA to LSA. There was no significant difference in ablation time between LSA and RSA (210.40 ± 179.77 vs. 192.19 ± 130.29 seconds, p = .748). There was no significant difference in procedure time, fluoroscopy time, radiation dose, or number of RF applications between the two groups. There was 1 (6.67%) serious adverse event in the LSA group and 1 (6.25%) in the RSA group due to femoral hematomas requiring blood transfusion or intervention. There was no significant difference in patient‐reported discomfort between LSA and RSA (16.43 ± 20.67 vs. 17.87 ± 28.08, p = .877). The study was stopped before full recruitment due to futility.
Conclusions
Retrograde LSA of the AVN does not reduce RF applications, procedure time, or radiation exposure compared with conventional RSA and cannot be recommended as a first‐line clinical approach.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Cardiology Research Department, Eastbourne District General Hospital, East Sussex Hospitals NHS Trust, Saint Leonards-on-Sea, East Sussex, UK.
- Institute of Cardiovascular Science, University College of London, London, UK.
- CVS Healthcare Ltd, Eastbourne, UK.
Zitieren
APA
Dulai, R., Sulke, N., Furniss, S. S., Malaweera, A., Lambiase, P. D., Patel, N., & Veasey, R. A. (2023). A randomized comparison of retrograde left‐sided versus anterograde right‐sided ablation of the atrioventricular junction. Clinical Cardiology. https://doi.org/10.1002/clc.24038
Vancouver
Dulai R, Sulke N, Furniss SS, Malaweera A, Lambiase PD, Patel N, et al. A randomized comparison of retrograde left‐sided versus anterograde right‐sided ablation of the atrioventricular junction. Clinical Cardiology. 2023. doi:10.1002/clc.24038
BibTeX
@article{Dulai2023,
author = {Dulai, Rajdip and Sulke, Neil and Furniss, Stephen S and Malaweera, Anura and Lambiase, Pier D and Patel, Nikhil and Veasey, Rick A},
title = {A randomized comparison of retrograde left‐sided versus anterograde right‐sided ablation of the atrioventricular junction},
journal = {Clinical Cardiology},
year = {2023},
doi = {10.1002/clc.24038}
}
EUVIMED