EUVIMEDEUVIMED entdecken
Crossref

Development and Validation of Chiral Supercritical Fluid Chromatographic Method for Rapid Separation of Viloxazine Using an Immobilized Amylose‐Based Chiral Stationary Phase

Srikanth Mannem, Srinuvasu Nakka, Rupak Raja, Nagaraju Devunuri

Chirality · 2026-12 · 38 (12)

DOI: 10.1002/chir.70168 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Chirality, online erschienen am 19.11.2026. Verfasst von Srikanth Mannem und 3 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 44 Literaturangaben. Gefördert von: Council of Scientific and Industrial Research, India, Department of Science and Technology, Ministry of Science and Technology, India.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Viloxazine is a chiral norepinephrine reuptake inhibitor for which reliable enantiomeric analysis is essential to ensure pharmacological consistency, safety, and regulatory compliance. This study presents a validated, rapid, and efficient supercritical fluid chromatographic (SFC) method for the enantiomeric separation and quantification of viloxazine using an immobilized amylose‐based chiral stationary phase. Baseline separation was obtained within 8 min with excellent chromatographic performance and resolution (Rs) of 3.09 and symmetric peak shapes. Although enantiomeric separation of viloxazine under SFC conditions has been reported previously, earlier studies primarily focused on chromatographic selectivity and chiral recognition mechanisms. In contrast, the present method was comprehensively validated as per ICH Q2(R2) recommendations and demonstrated excellent linearity (r = 0.9996 for both enantiomers), high precision (%RSD < 0.5% for peak area), good sensitivity, LOD, i.e., Limit of Detection (0.016 mg mL −1 ), and LOQ, i.e., Limit of Quantification (0.040 mg mL −1 ). Compared with previously reported NP‐HPLC and PO‐HPLC methods, the developed SFC method provides a shorter analysis time and lower organic solvent consumption while maintaining comparable analytical sensitivity. A comparative analytical greenness assessment using the AGREE metric yielded scores of 0.61, 0.58, and 0.56 for the developed SFC, PO‐HPLC, and NP‐HPLC methods, respectively, indicating a comparatively favorable overall environmental profile for the SFC method. These advantages establish the developed method as a practical and reliable analytical approach for routine enantiomeric purity assessment of viloxazine in pharmaceutical quality‐control laboratories.

Förderung

  • Council of Scientific and Industrial Research, India
  • Department of Science and Technology, Ministry of Science and Technology, India

Zitieren

APA

Mannem, S., Nakka, S., Raja, R., & Devunuri, N. (2026). Development and Validation of Chiral Supercritical Fluid Chromatographic Method for Rapid Separation of Viloxazine Using an Immobilized Amylose‐Based Chiral Stationary Phase. Chirality, 38(12). https://doi.org/10.1002/chir.70168

Vancouver

Mannem S, Nakka S, Raja R, Devunuri N. Development and Validation of Chiral Supercritical Fluid Chromatographic Method for Rapid Separation of Viloxazine Using an Immobilized Amylose‐Based Chiral Stationary Phase. Chirality. 2026;38(12). doi:10.1002/chir.70168

BibTeX
@article{Mannem2026,
  author = {Mannem, Srikanth and Nakka, Srinuvasu and Raja, Rupak and Devunuri, Nagaraju},
  title = {Development and Validation of Chiral Supercritical Fluid Chromatographic Method for Rapid Separation of Viloxazine Using an Immobilized Amylose‐Based Chiral Stationary Phase},
  journal = {Chirality},
  year = {2026},
  volume = {38},
  number = {12},
  doi = {10.1002/chir.70168}
}
Kostenlos starten →