Optimization of CEST MRI Reporter Protein Design Using Cation‐Pi Networks
Chemistry – A European Journal · 2025
DOI: 10.1002/chem.202501638 ↗Kurz gefasst
Fachartikel in der Zeitschrift Chemistry – A European Journal, 2025. Verfasst von David E Korenchan und 8 weiteren Autor:innen. Beteiligte Einrichtung: Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, 02129, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Cations, Peptides, Contrast Media. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 83 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIBIB NIH HHS, Massachusetts Life Sciences Center, NICHD NIH HHS.
Abstract (Originalsprache)
Nucleic acid‐based therapeutics, such as oncolytic virotherapy or gene therapy, would benefit greatly from a reporter gene that induces endogenous production of a protein biomarker to noninvasively track the delivery, persistence, and spread with imaging. Several chemical exchange saturation transfer (CEST) reporter proteins detectable by magnetic resonance imaging (MRI) have been demonstrated to have high sensitivity. However, to date none can provide strong CEST contrast at a distinct resonance from that of endogenous proteins, limiting their specificity. We investigated proteins and peptides containing tyrosine (Tyr), tryptophan (Trp), and lysine (Lys) residues that demonstrate CEST contrast shifted far downfield (4–10 ppm) from water. Although Tyr, Trp, and Lys exchangeable protons are typically not detectable under physiological conditions, those in our tested molecules are, having exchange rates of 400–2500 s −1 . The large chemical shift dispersion and rapid exchange rates are attributed to unique hydrogen bonding and cation‐π network interactions. These discoveries set the stage for designing a stable reporter protein with high detection specificity and sensitivity that can facilitate the in vivo monitoring of viral and gene therapies using MRI.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, 02129, USA.
- Department of Neurosurgery, Harvey Cushing Neuro-oncology Laboratories, Brigham and Women's Hospital, Boston, MA, 02115, USA.
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, 21205, USA.
- Department of Radiology, Johns Hopkins School of Medicine, Baltimore, MD, 21287, USA.
- Department of Chemical Engineering and Materials Science, Michigan State University, East Lansing, MI, 48824, USA.
- Department of Radiology, Michigan State University, East Lansing, MI, 48824, USA.
ORCID-Profile: David E Korenchan, Ethan J French, Assaf A Gilad, Christian T Farrar
Förderung
- NIBIB NIH HHS
- Massachusetts Life Sciences Center
- NICHD NIH HHS
- NIH HHS
- NCI NIH HHS
- National Institute of Biomedical Imaging and Bioengineering
- National Institutes of Health
- National Cancer Institute
Zitieren
APA
Korenchan, D. E., French, E. J., Runco, E., Dhakan, C. B., Yan, J., Nakashima, H., McMahon, M. T., Gilad, A. A., & Farrar, C. T. (2025). Optimization of CEST MRI Reporter Protein Design Using Cation‐Pi Networks. Chemistry – A European Journal. https://doi.org/10.1002/chem.202501638
Vancouver
Korenchan DE, French EJ, Runco E, Dhakan CB, Yan J, Nakashima H, et al. Optimization of CEST MRI Reporter Protein Design Using Cation‐Pi Networks. Chemistry – A European Journal. 2025. doi:10.1002/chem.202501638
BibTeX
@article{Korenchan2025,
author = {Korenchan, David E and French, Ethan J and Runco, Emerenziana and Dhakan, Chetan B and Yan, Jinwu and Nakashima, Hiroshi and McMahon, Michael T and Gilad, Assaf A and Farrar, Christian T},
title = {Optimization of CEST MRI Reporter Protein Design Using Cation‐Pi Networks},
journal = {Chemistry – A European Journal},
year = {2025},
doi = {10.1002/chem.202501638}
}
EUVIMED