EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

p ‐Sulfonatocalix[4]arene‐Based Ratiometric Fluorescence Chemosensor Array for the Differential Detection of Polycationic Peptides

Joana N. Martins, Márcia Pessêgo, Lucia Méndez‐Gómez, Hanieh Mahmoodi, Javier Montenegro, Luis Garcia‐Rio, João Carlos Lima, Nuno Basílio

ChemistryEurope · 2026-07 · 4 (7)

DOI: 10.1002/ceur.70333 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ChemistryEurope, online erschienen am 13.07.2026. Verfasst von Joana N. Martins und 7 weiteren Autor:innen. Die Arbeit nennt 68 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Arginine‐rich peptides and arginine‐rich motifs in proteins are important sensing targets owing to their critical role in several biological processes. Here we report a family of amphiphilic sulfonatocalix[4]arene‐pyrene (SC4‐nPy) conjugates as ratiometric fluorescence chemosensors for oligoarginine peptides. These fluorescent receptors are shown to bind the oligoarginine targets with high affinity and undergo a complexation‐induced aggregation phenomenon that can be conveniently monitored by the characteristic monomer‐excimer ratiometric fluorescence signal of the pyrene unit. As the critical aggregation concentration of the chemosensor‐peptide complex can be orthogonally tuned by amphiphilic nature of the SC4‐nPy receptor and by the number of arginine residues in the peptide chain, the SC4‐nPy conjugates allow the construction of ratiometric fluorescence chemosensor arrays capable of detecting and differentiating arginine‐rich peptides according to the number of cationic arginine residues in their sequences. To illustrate the utility of this approach, we demonstrate that the chemosensor array can distinguish subtle sequence variations in biologically relevant peptide motifs, such as the proteolytic cleavage sites of the coronavirus spike proteins of SARS‐CoV‐2 and MERS‐CoV.

Zitieren

APA

Martins, J. N., Pessêgo, M., Méndez‐Gómez, L., Mahmoodi, H., Montenegro, J., Garcia‐Rio, L., Lima, J. C., & Basílio, N. (2026). p ‐Sulfonatocalix[4]arene‐Based Ratiometric Fluorescence Chemosensor Array for the Differential Detection of Polycationic Peptides. ChemistryEurope, 4(7). https://doi.org/10.1002/ceur.70333

Vancouver

Martins JN, Pessêgo M, Méndez‐Gómez L, Mahmoodi H, Montenegro J, Garcia‐Rio L, et al. p ‐Sulfonatocalix[4]arene‐Based Ratiometric Fluorescence Chemosensor Array for the Differential Detection of Polycationic Peptides. ChemistryEurope. 2026;4(7). doi:10.1002/ceur.70333

BibTeX
@article{Martins2026,
  author = {Martins, Joana N. and Pessêgo, Márcia and Méndez‐Gómez, Lucia and Mahmoodi, Hanieh and Montenegro, Javier and Garcia‐Rio, Luis and Lima, João Carlos and Basílio, Nuno},
  title = {p ‐Sulfonatocalix[4]arene‐Based Ratiometric Fluorescence Chemosensor Array for the Differential Detection of Polycationic Peptides},
  journal = {ChemistryEurope},
  year = {2026},
  volume = {4},
  number = {7},
  doi = {10.1002/ceur.70333}
}
Kostenlos starten →