EUVIMEDEUVIMED entdecken
Crossref

Pre‐Test Evaluation of Ground Motion Sequence Effects on a Ten‐Story Cold‐Formed Steel Framed Building

Mohammed M. Eladly, Zhidong Zhang, Jiachen (Charlie) Zhang, Amanpreet Singh, Matthew S. Speicher, Tara C. Hutchinson, Benjamin W. Schafer

ce/papers · 2026-09 · 9 (2-3) · 2359-2363

DOI: 10.1002/cepa.70738 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ce/papers, online erschienen am 14.09.2026. Verfasst von Mohammed M. Eladly und 6 weiteren Autor:innen. Die Arbeit nennt 19 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Within the United States regulatory framework, cold‐formed steel (CFS) framed buildings in high seismic regions remain restricted to six‐story construction. To explore the viability of taller CFS systems and address urban demands for resilient and fire‐safe housing, a ten‐story CFS‐framed building was tested, under multidirectional increasing‐intensity ground motions in June 2025 at the University of California San Diego's Large High‐Performance Outdoor Shake Table (LHPOST6). Before performing physical experiments, extensive numerical studies were undertaken employing a high‐fidelity nonlinear finite element model constructed in Open‐SeesPy. The model provides detailed structural component modeling with consideration of inelastic material behavior and stability‐related nonlinearities. It also aims to capture buckling effects, and member and story‐level P‐δ and P‐Δ effects. This paper presents pre‐test predictions of the test building under sequential ground motions. The findings quantify the progressive accumulation of peak interstory drift ratios through sequential seismic events and evaluate whether damage from preceding lower‐intensity events significantly alters the building's response to subsequent high‐intensity ground motions compared to its response without prior damage.

Zitieren

APA

Eladly, M. M., Zhang, Z., Zhang, J. C., Singh, A., Speicher, M. S., Hutchinson, T. C., & Schafer, B. W. (2026). Pre‐Test Evaluation of Ground Motion Sequence Effects on a Ten‐Story Cold‐Formed Steel Framed Building. ce/papers, 9(2-3), 2359-2363. https://doi.org/10.1002/cepa.70738

Vancouver

Eladly MM, Zhang Z, Zhang JC, Singh A, Speicher MS, Hutchinson TC, et al. Pre‐Test Evaluation of Ground Motion Sequence Effects on a Ten‐Story Cold‐Formed Steel Framed Building. ce/papers. 2026;9(2-3):2359-2363. doi:10.1002/cepa.70738

BibTeX
@article{Eladly2026,
  author = {Eladly, Mohammed M. and Zhang, Zhidong and Zhang, Jiachen (Charlie) and Singh, Amanpreet and Speicher, Matthew S. and Hutchinson, Tara C. and Schafer, Benjamin W.},
  title = {Pre‐Test Evaluation of Ground Motion Sequence Effects on a Ten‐Story Cold‐Formed Steel Framed Building},
  journal = {ce/papers},
  year = {2026},
  volume = {9},
  number = {2-3},
  pages = {2359--2363},
  doi = {10.1002/cepa.70738}
}
Kostenlos starten →