Assessment of Design Provisions for High‐Strength Concrete‐Encased Steel Slender Columns in Fire
ce/papers · 2026-09 · 9 (2-3) · 887-891
DOI: 10.1002/cepa.70600 ↗Kurz gefasst
Fachartikel in der Zeitschrift ce/papers, online erschienen am 14.09.2026. Verfasst von Jie Li und 3 weiteren Autor:innen. Die Arbeit nennt 9 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Concrete‐encased steel (CES) columns offer high load‐carrying capacity and excellent fire resistance, making them attractive for high‐rise buildings. However, with the increasing use of high‐strength materials, the effectiveness of the EN 1994‐1‐2:2026 approaches for assessing the fire performance of CES columns remains unclear, and their applicability requires further investigation. To promote the rational application of high‐strength materials in CES columns, this study presents a systematic evaluation of the Eurocode fire design methods, aiming to examine their performance and identify potential directions for improvement. Based on a validated finite element model, an extensive parametric study was conducted, considering the effects of relative slenderness, load ratio, and material strength. The results indicate that the tabulated method may be overly conservative in some cases and may lead to unsafe predictions under specific parameter combinations. In addition, the simplified design method may result in potentially unsafe predictions when inappropriate thermal stress reduction factors are adopted. On the basis of the parametric analysis, supplementary design tables are proposed to improve the applicability and accuracy of the tabulated method, and preliminary recommendations on thermal stress reduction factors for high‐strength materials are discussed. The findings of this study may serve as a reference for the fire design, code development, and further research on CES columns.
Zitieren
APA
Li, J., Medall, D., Espinós, A., & Romero, M. L. (2026). Assessment of Design Provisions for High‐Strength Concrete‐Encased Steel Slender Columns in Fire. ce/papers, 9(2-3), 887-891. https://doi.org/10.1002/cepa.70600
Vancouver
Li J, Medall D, Espinós A, Romero ML. Assessment of Design Provisions for High‐Strength Concrete‐Encased Steel Slender Columns in Fire. ce/papers. 2026;9(2-3):887-891. doi:10.1002/cepa.70600
BibTeX
@article{Li2026,
author = {Li, Jie and Medall, David and Espinós, Ana and Romero, Manuel L.},
title = {Assessment of Design Provisions for High‐Strength Concrete‐Encased Steel Slender Columns in Fire},
journal = {ce/papers},
year = {2026},
volume = {9},
number = {2-3},
pages = {887--891},
doi = {10.1002/cepa.70600}
}