Axial load capacity of grouted inter‐modular connections for modular steel buildings: An experimental investigation
ce/papers · 2026-09 · 9 (2-3) · 904-909
DOI: 10.1002/cepa.70593 ↗Kurz gefasst
Fachartikel in der Zeitschrift ce/papers, online erschienen am 14.09.2026. Verfasst von Farhan Ahmed und 5 weiteren Autor:innen. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Modular Steel Buildings (MSBs) can offer advantages over conventional steel structures, including accelerated construction timelines and a reduced carbon footprint. Recently, grouted connections, originally developed for offshore wind turbines, have emerged as a viable alternative to traditional bolted inter‐modular connections. While bolted connections are susceptible to tolerance accumulation in high‐rise MSBs, potentially leading to misalignment and slip failure under lateral loads, grouted connections offer tolerance flexibility and superior lateral strength. In this study, experimental tests were conducted to investigate the axial load capacity of grouted tubular inter‐modular connections using high‐strength self‐compacting grout. Nine specimens were tested at an early stage (two days) to evaluate the influence of shear key spacing on load transfer behaviour. An inverse relationship was observed between shear key spacing and the axial capacity, with an increase in spacing from 60 mm to 90 mm leading to a 21% reduction in total load capacity, due to a decrease in the number of mobilised grout compression struts. When normalised per shear key set, however, larger spacings resulted in 6–15% higher resistance per strut, as closer spacing restricts strut development and reduces their effective load‐carrying capacity. Further studies are required to extend the present findings and assess the behaviour of grouted inter‐modular connections in modular steel buildings.
Zitieren
APA
Ahmed, F., Gkantou, M., Nikitas, G., Ferentinou, M., Bras, A., & |, M. R. (2026). Axial load capacity of grouted inter‐modular connections for modular steel buildings: An experimental investigation. ce/papers, 9(2-3), 904-909. https://doi.org/10.1002/cepa.70593
Vancouver
Ahmed F, Gkantou M, Nikitas G, Ferentinou M, Bras A, | MR. Axial load capacity of grouted inter‐modular connections for modular steel buildings: An experimental investigation. ce/papers. 2026;9(2-3):904-909. doi:10.1002/cepa.70593
BibTeX
@article{Ahmed2026,
author = {Ahmed, Farhan and Gkantou, Michaela and Nikitas, Georgios and Ferentinou, Maria and Bras, Ana and |, Mike Riley},
title = {Axial load capacity of grouted inter‐modular connections for modular steel buildings: An experimental investigation},
journal = {ce/papers},
year = {2026},
volume = {9},
number = {2-3},
pages = {904--909},
doi = {10.1002/cepa.70593}
}