Comparative fire performance of steel and timber purlins
ce/papers · 2026-09 · 9 (2-3) · 2451-2456
DOI: 10.1002/cepa.70543 ↗Kurz gefasst
Fachartikel in der Zeitschrift ce/papers, online erschienen am 14.09.2026. Verfasst von Oliver Bahr. Die Arbeit nennt 10 Literaturangaben.
Abstract (Originalsprache)
Steel halls are widely used for their economic efficiency. However, achieving a fire rating of R30 is challenging. It often requires costly fire protection or excessive oversizing. In fire scenarios, rafters rather than columns typically govern failure due to lateral‐torsional buckling. This study focuses on the role of purlins in rafter stabilization under fire. In a bottom‐up approach the purlins are modelled as simply supported beams, without the surrounding steel frame. The fire performance of different purlin types (Z‐section, I‐section, timber) are analyzed using the FE software ‘Safir’. Results show different load‐behaviour of steel and timber purlins. Steel purlins quickly reach critical temperature, providing less stabilization to the rafter than the timber purlin. These findings emphasize both the choice of purlin type and material.
Zitieren
APA
Bahr, O. (2026). Comparative fire performance of steel and timber purlins. ce/papers, 9(2-3), 2451-2456. https://doi.org/10.1002/cepa.70543
Vancouver
Bahr O. Comparative fire performance of steel and timber purlins. ce/papers. 2026;9(2-3):2451-2456. doi:10.1002/cepa.70543
BibTeX
@article{Bahr2026,
author = {Bahr, Oliver},
title = {Comparative fire performance of steel and timber purlins},
journal = {ce/papers},
year = {2026},
volume = {9},
number = {2-3},
pages = {2451--2456},
doi = {10.1002/cepa.70543}
}
EUVIMED