EUVIMEDEUVIMED entdecken
Crossref

Comparative fire performance of steel and timber purlins

Oliver Bahr

ce/papers · 2026-09 · 9 (2-3) · 2451-2456

DOI: 10.1002/cepa.70543 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ce/papers, online erschienen am 14.09.2026. Verfasst von Oliver Bahr. Die Arbeit nennt 10 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Steel halls are widely used for their economic efficiency. However, achieving a fire rating of R30 is challenging. It often requires costly fire protection or excessive oversizing. In fire scenarios, rafters rather than columns typically govern failure due to lateral‐torsional buckling. This study focuses on the role of purlins in rafter stabilization under fire. In a bottom‐up approach the purlins are modelled as simply supported beams, without the surrounding steel frame. The fire performance of different purlin types (Z‐section, I‐section, timber) are analyzed using the FE software ‘Safir’. Results show different load‐behaviour of steel and timber purlins. Steel purlins quickly reach critical temperature, providing less stabilization to the rafter than the timber purlin. These findings emphasize both the choice of purlin type and material.

Zitieren

APA

Bahr, O. (2026). Comparative fire performance of steel and timber purlins. ce/papers, 9(2-3), 2451-2456. https://doi.org/10.1002/cepa.70543

Vancouver

Bahr O. Comparative fire performance of steel and timber purlins. ce/papers. 2026;9(2-3):2451-2456. doi:10.1002/cepa.70543

BibTeX
@article{Bahr2026,
  author = {Bahr, Oliver},
  title = {Comparative fire performance of steel and timber purlins},
  journal = {ce/papers},
  year = {2026},
  volume = {9},
  number = {2-3},
  pages = {2451--2456},
  doi = {10.1002/cepa.70543}
}