Abstract (Originalsprache)
Sway‐sensitive steel portal frames frequently include pinned–pinned intermediate columns and web‐tapered members, leading to reduced lateral stiffness and increased sensitivity to global imperfections. Current design approaches often reduce sway buckling to an equivalent member buckling problem through effective length factors or slenderness‐based scaling of elastic buckling modes. This paper demonstrates that such reductions are mechanically inconsistent for sway systems. A Eurocode‐compatible design methodology is proposed in which sway effects are treated explicitly as imperfection‐induced bending moments derived from global sway eigenmodes and superimposed on second‐order analysis results.
Zitieren
APA
Vaszilievits‐Sömjén, B., Szalai, J., & White, D. W. (2026). Global Buckling Design of Sway‐Sensitive Steel Portal Frames According to Eurocode. ce/papers, 9(2-3), 1980-1986. https://doi.org/10.1002/cepa.70518
Vancouver
Vaszilievits‐Sömjén B, Szalai J, White DW. Global Buckling Design of Sway‐Sensitive Steel Portal Frames According to Eurocode. ce/papers. 2026;9(2-3):1980-1986. doi:10.1002/cepa.70518
BibTeX
@article{VaszilievitsSmjn2026,
author = {Vaszilievits‐Sömjén, Bálint and Szalai, József and White, Donald W.},
title = {Global Buckling Design of Sway‐Sensitive Steel Portal Frames According to Eurocode},
journal = {ce/papers},
year = {2026},
volume = {9},
number = {2-3},
pages = {1980--1986},
doi = {10.1002/cepa.70518}
}